EU Science Hub

Results of time-of-flight transmission measurements for natV at a 50 m station of GELINA: Description of GELINA data to be stored in the EXFOR data base

Abstract: 
Transmission measurements have been performed at the time-of-flight facility GELINA to determine neutron resonance parameters for 51V. The measurements have been carried out at a 50 m transmission station at a moderated neutron beam using a Li-glass scintillator with the accelerator operating at 800 Hz. This report provides the experimental details required to deliver the data to the EXFOR data library which is maintained by the Nuclear Data Section of the International Atomic Energy Agency (NDS/IAEA) and the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (NEA/OECD). The experimental conditions and data reduction procedures are described. In addition, the full covariance information based on the AGS concept is given such that nuclear reaction model parameters together with their covariances can be derived in a least squares adjustment to the data.