Table 3: Modelled organ equivalent doses from backscatter scanners
|
Organ equivalent dose (μSv) |
Combined backscatter/transmission scanner |
Backscatter scanner |
RCP-AM |
RCP-AF |
Katja |
RCP-AM |
RCP-AF |
Katja |
Thyroid |
0.248 |
0.264 |
0.443 |
0.045 |
0.047 |
0.046 |
Urinary bladder wall |
0.115 |
0.203 |
0.177 |
0.020 |
0.034 |
0.017 |
Breast, total |
0.269 |
0.239 |
0.410 |
0.021 |
0.045 |
0.045 |
Eye lenses |
0.514 |
0.390 |
0.686 |
0.060 |
0.071 |
0.069 |
Lymphatic nodes |
0.165 |
0.172 |
0.169 |
0.036 |
0.031 |
0.028 |
Muscle tissue |
0.189 |
0.182 |
0.148 |
0.009 |
0.034 |
0.033 |
Ovaries |
|
0.083 |
0.050 |
|
0.013 |
0.012 |
Skin, total |
0.398 |
0.418 |
0.382 |
0.089 |
0.091 |
0.091 |
Testes |
0.257 |
|
|
0.047 |
|
|
Foetus total body |
|
|
0.122 |
|
|
0.012 |
Effective dose |
0.139 |
(0.160) |
0.025 |
(0.022) |
Source: SCENIHR, Health effects of security scanners for passenger
screening (based on X-ray technology), (2012),
3.5 Dosimetric aspects, pp.22-27