Decision |
Product family, product /Intended use |
AoC system |
Technical specification |
Body function |
95/467/EC |
Chimneys, flues and specific products (1/1) :
Prefabricated chimneys (storey height elements), flue liners (elements or blocks), multi-shell chimney (elements or blocks), single walled chimneys and attached chimneys (chimneys)
|
System 2+
|
EN 13063-1:2005
EN 13063-2:2005
|
FPC Certification Body
|
95/467/EC |
Gypsum products (1/4) :
Plasterboards and ceiling elements with thin laminations, fibrous gypsum boards, fibrous gypsum plaster casts, and composite panels (laminates), in which the incorporated material is placed on a face susceptible to be explosed to fire, including relevant ancillary products (in walls, partitions or ceilings (or lining thereof) subject to reaction to fire requirements)
|
System 3
|
EN 13963:2005
EN 13963:2005/AC:2006
EN 520:2004
|
Testing Laboratory
|
95/467/EC |
Gypsum products (2/4) :
Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings)
|
System 3
|
EN 520:2004
|
Testing Laboratory
|
95/467/EC |
Gypsum products (3/4) :
Plasterboards, including relevant ancillary products (for stiffening timber-framed windload bearing walls or timber roof struss structures)
|
System 3
|
EN 520:2004
|
Testing Laboratory
|
96/577/EC |
Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) :
Smoke and heat exhaust ventilation systems-kits (fire safety)
|
System 1
|
EN 12101-3:2002
|
Inspection Body
Testing Laboratory
Product Certification Body
|
96/580/EC |
Curtain wallings (1/1) :
Curtain wall kits (as external walls not subject to reaction to fire requirements)
|
System 3
|
EN 13830:2003
|
Testing Laboratory
|
96/580/EC |
Curtain wallings (1/1) :
Curtain wall kits (as external walls subject to reaction to fire requirements)
|
System 1
|
EN 13830:2003
|
Inspection Body
Testing Laboratory
Product Certification Body
|
96/582/EC |
Metal anchors for use in concrete (mechanical fasteners) :
Metal anchors for use in concrete (heavy-duty type) (for fixing and/or supporting concrete structural elements or heavy units such as cladding and suspended ceilings)
|
System 1
|
ETAG 001 - 1
ETAG 001 - 2
ETAG 001 - 3
ETAG 001 - 4
ETAG 001 - 5
ETAG 001 - 6
|
Inspection Body
Testing Laboratory
Product Certification Body
|
97/176/EC |
Structural timber products (1/3) :
Solid structural timber products; Kits (trusses, floors, walls, roofs, frames) (bridges, railtracks and buildings)
|
System 2+
|
EN 14250:2004
|
Inspection Body
|
97/176/EC |
Structural timber products (1/3) :
Solid structural timber products: Elements (bridge elements, truss elements, sleepers, floor elements, wall elements, roof elements such as beams, arches, joists, rafters, columns, poles, piles) (bridges, railtracks and buildings)
|
System 2+
|
EN 14081-1:2005
|
FPC Certification Body
|
97/176/EC |
Structural timber products (1/3) :
Solid structural timber products: Elements (bridge elements, truss elements, sleepers, floor elements, wall elements, roof elements such as beams, arches, joists, rafters, columns, poles, piles) (bridges, railtracks and buildings)
|
System 1
|
EN 14374:2004
|
FPC Certification Body
|
97/176/EC |
Structural timber products (1/3) :
Solid structural timber products; Kits (trusses, floors, walls, roofs, frames) (bridges, railtracks and buildings)
|
System 1
|
EN 14374:2004
|
Inspection Body
Testing Laboratory
Product Certification Body
|
97/176/EC |
Structural timber products (2/3) :
Structural glued laminated products and other glued timber products: Elements (bridge elements, truss elements, floor elements, wall elements, roof elements such as beams, arches, joists, rafters, columns, poles, piles) (for bridges and buildings)
|
System 1
|
EN 14080:2005
|
Inspection Body
Testing Laboratory
Product Certification Body
|
97/462/EC |
Wood-based panels (1/2) :
Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external application)
|
System 1
|
EN 13986:2002
|
Inspection Body
Testing Laboratory
Product Certification Body
|
97/462/EC |
Wood-based panels (1/2) :
Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external applications)
|
System 2+
|
EN 13986:2002
|
Inspection Body
|
97/462/EC |
Wood-based panels (2/2) :
Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
|
System 3
|
EN 13986:2002
|
Testing Laboratory
|
97/462/EC |
Wood-based panels (2/2) :
Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
|
System 1
|
EN 13986:2002
|
Inspection Body
Testing Laboratory
Product Certification Body
|
97/463/EC |
Plastic anchors for use in concrete and masonry (1/1) :
Plastic anchors for use in concrete and masonry (for use in systems, such as facade systems, for fixing or supporting elements which contribute to the stability of the systems)
|
System 2+
|
ETAG 001 - 6
ETAG 014
|
FPC Certification Body
|
97/555/EC |
Cements, building limes and other hydraulic binders :
Common cements, including:<BR>-Portland cement,<BR>-Portland composite cements: Portland-slag cement, Portland-silica fume cement, Portland-pozzolana cement, Portland-fly ash cement, Portland-burnt shale cement, Portland-limestone cement, Portland composite cement,<BR>-Blastfurnace cements,<BR>-Pozzolanic cements,<BR>-Composite cements (preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products)
|
System 1+
|
EN 197-1:2000
EN 197-1:2000/ A1:2004
|
Inspection Body
Testing Laboratory
Product Certification Body
|
97/556/EC |
External thermal insulation composite systems/kits with rendering (ETICS)(1/1) :
External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)
|
System 2+
|
ETAG 004
|
FPC Certification Body
Inspection Body
|
97/556/EC |
External thermal insulation composite systems/kits with rendering (ETICS)(1/1) :
External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)
|
System 1
|
ETAG 004
|
FPC Certification Body
Inspection Body
Testing Laboratory
Product Certification Body
|
97/638/EC |
Fasteners for structural timber products (1/1) :
Nailing plates (for structural timber products)
Shear plates (for structural timber products)
Punched nail plates (for structural timber products)
Toothed-plate connectors (for structural timber products)
|
System 2+
|
ETAG 015
|
FPC Certification Body
|
97/740/EC |
Masonry and related products (1/3) :
Factory-made, designed masonry mortars (in walls, columns and partitions)
|
System 2+
|
EN 998-2:2003
|
FPC Certification Body
|
97/740/EC |
Masonry and related products (1/3) :
Masonry units category I (in walls, columns and partitions)
|
System 2+
|
EN 771-1:2003
EN 771-1:2003/A1:2005
EN 771-2:2003
EN 771-2:2003/A1:2005
EN 771-3:2003
EN 771-3:2003/A1:2005
EN 771-4:2003
EN 771-4:2003/A1:2005
|
FPC Certification Body
|
97/808/EC |
Floorings (2/2) :
Floor screed materials (for internal uses)
|
System 1
|
EN 13813:2002
|
Inspection Body
Testing Laboratory
Product Certification Body
|
97/808/EC |
Floorings (2/2) :
Floor screed materials (for internal uses)
|
System 3
|
EN 13813:2002
|
Testing Laboratory
|
97/808/EC |
Floorings (2/2) :
Rigid flooring products<BR>(a) Components: paving units, tiles, mosaics, parquet, decking of mesh or sheet, floor gratings, rigid laminated floorings, wood based products (for internal uses including enclosed public transport premises)
|
System 3
|
EN 14342:2005
|
Testing Laboratory
|
98/213/EC |
Internal partition kits (1/5) :
Internal partition kits (for uses subject to reaction to fire requirements)
|
System 3
|
ETAG 003
|
Testing Laboratory
|
98/213/EC |
Internal partition kits (1/5) :
Internal partition kits (for uses subject to reaction to fire requirements)
|
System 1
|
ETAG 003
|
Inspection Body
Testing Laboratory
Product Certification Body
|
98/213/EC |
Internal partition kits (2/5) :
Internal partition kits (for fire compartmentation)
|
System 3
|
ETAG 003
|
Testing Laboratory
|
98/213/EC |
Internal partition kits (3/5) :
Internal partition kits (for uses subject to regulations on dangerous substances)
|
System 3
|
ETAG 003
|
Testing Laboratory
|
98/213/EC |
Internal partition kits (4/5) :
Internal partition kits (for uses liable to present "safety-in-use" risks and subject to such regulations)
|
System 3
|
ETAG 003
|
Testing Laboratory
|
98/279/EC |
Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1) :
Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: panels made of an insulating material (or a combination of an insulating material and other materials), consisting of shuttering leaves linked by spacers (for the construction of external and internal walls not subject to fire regulations, in buildings)
|
System 2+
|
ETAG 009
|
FPC Certification Body
Inspection Body
|
98/279/EC |
Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1) :
Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)
|
System 1
|
ETAG 009
|
FPC Certification Body
Inspection Body
Testing Laboratory
Product Certification Body
|
98/436/EC |
Roof coverings, rooflights, roof windows and ancillary products (2/6) :
Rooflights (for uses subject to reaction to fire regulations)
|
System 3
|
EN 1873:2005
|
Testing Laboratory
|
98/436/EC |
Roof coverings, rooflights, roof windows and ancillary products (2/6) :
Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations)
|
System 3
|
EN 544:2005
|
Testing Laboratory
|
98/436/EC |
Roof coverings, rooflights, roof windows and ancillary products (2/6) :
Rooflights (for uses subject to reaction to fire regulations)
|
System 1
|
EN 1873:2005
|
Inspection Body
Testing Laboratory
Product Certification Body
|
98/436/EC |
Roof coverings, rooflights, roof windows and ancillary products (2/6) :
Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations)
|
System 1
|
EN 1304:2005
|
Inspection Body
Testing Laboratory
Product Certification Body
|
98/436/EC |
Roof coverings, rooflights, roof windows and ancillary products (3/6) :
Rooflights (for uses subject to external fire performance regulations)
|
System 3
|
EN 1873:2005
|
Testing Laboratory
|
98/436/EC |
Roof coverings, rooflights, roof windows and ancillary products (3/6) :
Roofing tiles, slates, stones and shingles (for uses subject to external fire performance regulations)
|
System 3
|
EN 544:2005
|
Testing Laboratory
|
98/437/EC |
Internal and external wall and ceiling finishes (1/5) :
Suspended ceilings (kits) (as internal or external finishes used for fire protection of ceilings)
|
System 3
|
EN 13964:2004
|
Testing Laboratory
|
98/437/EC |
Internal and external wall and ceiling finishes (2/5) :
Suspended ceilings (kits) (as internal or external finish in ceilings subject to safety in use requirements)
|
System 3
|
EN 13964:2004
|
Testing Laboratory
|
98/437/EC |
Internal and external wall and ceiling finishes (2/5) :
Panels (as internal or external stiffening elements in walls or ceilings)
|
System 3
|
EN 438-7:2005
|
Testing Laboratory
|
98/437/EC |
Internal and external wall and ceiling finishes (3/5) :
Panels (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
|
System 3
|
EN 438-7:2005
|
Testing Laboratory
|
98/437/EC |
Internal and external wall and ceiling finishes (3/5) :
Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations)
|
System 3
|
EN 13964:2004
|
Testing Laboratory
|
98/437/EC |
Internal and external wall and ceiling finishes (3/5) :
Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations)
|
System 1
|
EN 13964:2004
|
Testing Laboratory
Product Certification Body
|
98/437/EC |
Internal and external wall and ceiling finishes (4/5) :
Suspended ceilings (kits) (as internal or external finishes in walls or ceilings subject to regulations on dangerous substances)
|
System 3
|
EN 13964:2004
|
Testing Laboratory
|
98/598/EC |
Aggregates for uses with high safety requirements (2/2) :
Aggregates and fillers for concrete, mortar and grout (in buildings, roads and other civil engineering work)
|
System 2+
|
EN 12620:2002
EN 13055-1:2002
EN 13139:2002
|
FPC Certification Body
|
98/600/EC |
Self-supporting translucent roof kits (except glass-based kits) (1/3) :
Self-supporting translucent roof kits (except glass-based kits) (for use in roofs and roof finishes)
|
System 3
|
ETAG 010
|
Testing Laboratory
|
98/600/EC |
Self-supporting translucent roof kits (except glass-based kits) (2/3) :
Self-supporting translucent roof kits (except glass-based kits) (for uses subject to external fire performance regulations)
|
System 3
|
ETAG 010
|
Testing Laboratory
|
98/600/EC |
Self-supporting translucent roof kits (except glass-based kits) (3/3) :
Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
|
System 3
|
ETAG 010
|
Testing Laboratory
|
98/600/EC |
Self-supporting translucent roof kits (except glass-based kits) (3/3) :
Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
|
System 1
|
ETAG 010
|
Inspection Body
Testing Laboratory
Product Certification Body
|
99/89/EC |
Prefabricated stair kits (1/2) :
Prefabricated stair kits (for dwellings and other buildings)
|
System 2+
|
ETAG 008
|
FPC Certification Body
|
99/89/EC |
Prefabricated stair kits (2/2) :
Prefabricated stair kits (for uses subject to reaction to fire regulations)
|
System 1
|
ETAG 008
|
Inspection Body
Testing Laboratory
Product Certification Body
|
99/89/EC |
Prefabricated stair kits (2/2) :
Prefabricated stair kits (for uses subject to reaction to fire regulations)
|
System 3
|
ETAG 008
|
Testing Laboratory
|
99/90/EC |
Membranes (1/3) :
Damp proofing sheets (in buildings)
|
System 2+
|
EN 13967:2004
EN 13969:2004
|
FPC Certification Body
|
99/90/EC |
Membranes (1/3) :
Roof sheets (in buildings)
|
System 2+
|
EN 13707:2004
EN 13956:2005
EN 13956:2005/AC:2006
|
FPC Certification Body
|
99/90/EC |
Membranes (1/3) :
Water vapour control layers (in buildings)
|
System 3
|
EN 13859-1:2005
EN 13970:2004
EN 13984:2004
|
Testing Laboratory
|
99/90/EC |
Membranes (1/3) :
Roof underlays (in buildings)
|
System 3
|
EN 13859-1:2005
|
Testing Laboratory
|
99/90/EC |
Membranes (2/3) :
Roof sheets (for uses subject to reaction to fire regulations)
|
System 3
|
EN 13707:2004
EN 13956:2005
EN 13956:2005/AC:2006
|
Testing Laboratory
|
99/90/EC |
Membranes (2/3) :
Roof underlays (for uses subject to reaction to fire regulations)
|
System 3
|
EN 13859-1:2005
|
Testing Laboratory
|
99/90/EC |
Membranes (2/3) :
Damp proofing sheets (for uses subject to reaction to fire regulations)
|
System 1
|
EN 13967:2004
EN 13969:2004
|
Inspection Body
Testing Laboratory
Product Certification Body
|
99/90/EC |
Membranes (2/3) :
Water vapour control layers (for uses subject to reaction to fire regulations)
|
System 1
|
EN 13970:2004
EN 13984:2004
|
Inspection Body
Testing Laboratory
Product Certification Body
|
99/90/EC |
Membranes (2/3) :
Roof sheets (for uses subject to reaction to fire regulations)
|
System 1
|
EN 13707:2004
EN 13956:2005
EN 13956:2005/AC:2006
|
Inspection Body
Testing Laboratory
Product Certification Body
|
99/90/EC |
Membranes (2/3) :
Roof underlays (for uses subject to reaction to fire regulations)
|
System 1
|
EN 13859-1:2005
|
Inspection Body
Testing Laboratory
Product Certification Body
|
99/90/EC |
Membranes (2/3) :
Damp proofing sheets (for uses subject to reaction to fire regulations)
|
System 3
|
EN 13967:2004
EN 13969:2004
|
Testing Laboratory
|
99/90/EC |
Membranes (3/3) :
Roof sheets (for uses subject to external fire performance regulations)
|
System 3
|
EN 13707:2004
EN 13956:2005
EN 13956:2005/AC:2006
|
Testing Laboratory
|
99/90/EC |
Membranes (3/3) :
Roof underlays (for uses subject to external fire performance regulations)
|
System 3
|
EN 13859-1:2005
|
Testing Laboratory
|
99/91/EC |
Thermal insulating products (2/2) :
Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
|
System 1
|
EN 13162:2001
EN 13162:2001/AC:2005
EN 13163:2001
EN 13163:2001/AC:2005
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13164:2001/AC:2005
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13165:2001/A2:2004
EN 13165:2001/AC:2005
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13166:2001/AC:2005
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13167:2001/AC:2005
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13168:2001/AC:2005
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13169:2001/AC:2005
EN 13170:2001
EN 13170:2001/AC:2005
EN 13171:2001
EN 13171:2001/ A1:2004
EN 13171:2001/AC:2005
|
Inspection Body
Testing Laboratory
Product Certification Body
|
99/91/EC |
Thermal insulating products (2/2) :
Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
|
System 3
|
EN 13162:2001
EN 13162:2001/AC:2005
EN 13163:2001
EN 13163:2001/AC:2005
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13164:2001/AC:2005
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13165:2001/A2:2004
EN 13165:2001/AC:2005
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13166:2001/AC:2005
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13167:2001/AC:2005
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13168:2001/AC:2005
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13169:2001/AC:2005
EN 13170:2001
EN 13170:2001/AC:2005
EN 13171:2001
EN 13171:2001/ A1:2004
EN 13171:2001/AC:2005
|
Testing Laboratory
|
99/92/EC |
Light composite wood-based beams and columns (1/1) :
Light composite wood-based beams and columns (including T-beams, i.e. beam/slab combinations) (in buildings)
|
System 1
|
ETAG 011
|
Inspection Body
Testing Laboratory
Product Certification Body
|
99/93/EC |
Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
Windows (with or without related hardware) (any other)
|
System 3
|
EN 14351-1:2006
|
Testing Laboratory
|
99/93/EC |
Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
|
System 3
|
EN 13241-1:2003
EN 14351-1:2006
|
Testing Laboratory
|
99/93/EC |
Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes)
|
System 1
|
EN 1125:1997/A1:2001
EN 1154:1996/A1:2002
EN 1155:1997/A1:2002
EN 1158:1997/A1:2002
EN 1158:1997/A1:2002/AC:2006
EN 12209:2003
EN 12209:2003/AC:2005
EN 179:1997/A1:2001
EN 1935:2002
EN 1935:2002/AC:2003
|
Inspection Body
Testing Laboratory
Product Certification Body
|
99/93/EC |
Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
Doors and gates (with or without related hardware) (fire/smoke compartmentation and on escape routes)
|
System 1
|
EN 14351-1:2006
|
Inspection Body
Testing Laboratory
Product Certification Body
|
99/455/EC |
Timber frame and log prefabricated building kits (1/1) :
Timber frame and log prefabricated building kits (as defined in Annex I) (in building works)
|
System 1
|
ETAG 007
ETAG 012
|
Inspection Body
Testing Laboratory
Product Certification Body
|
99/470/EC |
Construction adhesives (1/2) :
Adhesives for tiles (for internal and external uses in buildings and other civil engineering works)
|
System 3
|
EN 12004:2001/A1:2002
EN 12004:2001/A1:2002/AC:2002
|
Testing Laboratory
|
99/470/EC |
Construction adhesives (2/2) :
Adhesives for tiles (for uses subject to reaction to fire regulations)
|
System 1
|
EN 12004:2001/A1:2002
EN 12004:2001/A1:2002/AC:2002
|
Testing Laboratory
|
99/470/EC |
Construction adhesives (2/2) :
Adhesives for tiles (for uses subject to reaction to fire regulations)
|
System 3
|
EN 12004:2001/A1:2002
EN 12004:2001/A1:2002/AC:2002
|
Testing Laboratory
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (1/6) :
Insulating glass units (for use in a glazed assembly intended specifically to provide fire resistance)
|
System 1
|
EN 1279-5:2005
|
Inspection Body
Testing Laboratory
Product Certification Body
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (1/6) :
Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
|
System 1
|
EN 1096-4:2004
EN 12150-2:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1863-2:2004
|
Inspection Body
Testing Laboratory
Product Certification Body
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (2/6) :
Insulating glass units (for uses subject to reaction to fire regulations)
|
System 3
|
EN 1279-5:2005
|
Testing Laboratory
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (2/6) :
Flat or curved glass panels (for uses subject to reaction to fire regulations)
|
System 3
|
EN 1096-4:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1863-2:2004
|
Testing Laboratory
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (3/6) :
Insulating glass units (for uses subject to external fire performance regulations)
|
System 3
|
EN 1279-5:2005
|
Testing Laboratory
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (3/6) :
Flat or curved glass panels (for uses subject to external fire performance regulations)
|
System 3
|
EN 1096-4:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1863-2:2004
|
Testing Laboratory
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (4/6) :
Insulating glass units (for other uses liable to present "safety-in-use" risks and subject to such regulations)
|
System 3
|
EN 1279-5:2005
|
Testing Laboratory
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (4/6) :
Insulating glass units (for use as anti-bullet, or anti-explosion glazing)
|
System 1
|
EN 1279-5:2005
|
Inspection Body
Testing Laboratory
Product Certification Body
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (4/6) :
Flat or curved glass panels (for other uses liable to present "safety-in-use" risks and subject to such regulations)
|
System 3
|
EN 1096-4:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1863-2:2004
|
Testing Laboratory
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (4/6) :
Flat or curved glass panels (for use as anti-bullet, or anti-explosion glazing)
|
System 1
|
EN 1096-4:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1863-2:2004
|
Inspection Body
Testing Laboratory
Product Certification Body
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (5/6) :
Insulating glass units (for uses relating to energy conservation and/or noise reduction)
|
System 3
|
EN 1279-5:2005
|
Testing Laboratory
|
2000/245/EC |
Flat glass, profiled glass and glass-block products (5/6) :
Flat or curved glass panels (specially treated) (for uses relating to energy conservation and/or noise reduction)
|
System 3
|
EN 1096-4:2004
EN 12150-2:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1863-2:2004
|
Testing Laboratory
|