European Commission - Growth

For a better experience, please enable Javascript!


Notification

Found : 10
  Body :

L.S. Fire Testing Institute Srl
Via della Bonifica, 4
64010 - Controguerra (TE)
Country : Italy

Phone : +39031890588 - +39031890375
Fax : +390313532853

Email : labo@lsfire.it
Website : www.lsfire.it

Notified Body number : 2479

Last approval date : 03/07/2013
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
Regulation (EU) No 305/2011 - Construction products
Last approval date : 22/01/2021                 Version(s): 1 2 3 4 5 6 7

Decision Product family, product /Intended use AVCP system Technical specification Body function
95/467/EC Gypsum products (1/4) :
• Plasterboards and ceiling elements with thin laminations, fibrous gypsum boards, fibrous gypsum plaster casts, and composite panels (laminates), in which the incorporated material is placed on a face susceptible to be explosed to fire, including relevant ancillary products (in walls, partitions or ceilings (or lining thereof) subject to reaction to fire requirements)
System 3
EN 13815:2006
EN 13915:2007
EN 13950:2005
EN 13950:2014
EN 14190:2005
EN 14190:2014
EN 15283-1:2008+A1:2009
EN 15283-2:2008+A1:2009
EN 520:2004+A1:2009
Testing Laboratory
95/467/EC Gypsum products (2/4) :
• Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings)
System 3
EN 14246:2006
EN 14246:2006/AC:2007
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 3
EN 13830:2003
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 1
EN 13830:2003
Product Certification Body
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external application)
System 1
EN 13986:2004
EN 13986:2004+A1:2015
Product Certification Body
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 3
EN 13986:2004
EN 13986:2004+A1:2015
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 1
EN 14041:2004
EN 14041:2004/AC:2006
EN 14904:2006
Product Certification Body
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 1
EN 13813:2002
Product Certification Body
97/808/EC Floorings (2/2) :
• Rigid flooring products<BR>(a) Components: paving units, tiles, mosaics, parquet, decking of mesh or sheet, floor gratings, rigid laminated floorings, wood based products (for internal uses including enclosed public transport premises)
System 1
EN 14342:2013
EN 15285:2008
EN 15285:2008/AC:2008
Product Certification Body
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 3
EN 13813:2002
Testing Laboratory
97/808/EC Floorings (2/2) :
• Rigid flooring products<BR>(a) Components: paving units, tiles, mosaics, parquet, decking of mesh or sheet, floor gratings, rigid laminated floorings, wood based products (for internal uses including enclosed public transport premises)
System 3
EN 14342:2013
EN 15285:2008
EN 15285:2008/AC:2008
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 3
EN 14041:2004
EN 14041:2004/AC:2006
EN 14904:2006
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Rooflights (for uses subject to reaction to fire regulations)
System 3
EN 14963:2006
EN 1873:2005
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Factory-bonded composite or sandwich panels (for uses subject to reaction to fire regulations)
System 3
EN 14509:2013
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations)
System 3
EN 14964:2006
EN 492:2012
EN 544:2011
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Flat and profiled sheets (for uses subject to reaction to fire regulations)
System 3
EN 1013:2012+A1:2014
EN 14782:2006
EN 16153:2013
EN 16153:2013+A1:2015
EN 494:2012+A1:2015
EN 534:2006+A1:2010
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Flat and profiled sheets (for uses subject to reaction to fire regulations)
System 1
EN 1013:2012+A1:2014
EN 16153:2013
EN 16153:2013+A1:2015
Product Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Rooflights (for uses subject to reaction to fire regulations)
System 1
EN 14963:2006
Product Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Factory-bonded composite or sandwich panels (for uses subject to reaction to fire regulations)
System 1
EN 14509:2013
Product Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations)
System 1
EN 14964:2006
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (1/5) :
• Panels (as internal or external finishes, as complete elements, used for fire protection of walls or ceilings)
System 3
EN 15102:2007+A1:2011
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Panels (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 3
EN 1013:2012+A1:2014
EN 438-7:2005
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Sidings (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 3
EN 13245-2:2008
EN 13245-2:2008/AC:2009
EN 14915:2013
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Tiles (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 3
EN 15286:2013
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations)
System 3
EN 13964:2004
EN 13964:2004/A1:2006
EN 13964:2014
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Shingles (as external finishes in walls or ceilings subject to reaction to fire regulations)
System 3
EN 12467:2012
EN 16153:2013+A1:2015
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Coverings in roll form (as internal finishes in walls or ceilings subject to reaction to fire regulations)
System 3
EN 14716:2004
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations)
System 1
EN 13964:2004
EN 13964:2004/A1:2006
EN 13964:2014
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Shingles (as external finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 16153:2013+A1:2015
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Coverings in roll form (as internal finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 15102:2007+A1:2011
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Panels (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 1013:2012+A1:2014
EN 438-7:2005
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Sidings (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 13245-2:2008
EN 13245-2:2008/AC:2009
EN 14915:2013
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Tiles (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 15286:2013
Product Certification Body
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 3
EN 13859-2:2010
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2013
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 3
EN 13707:2004+A2:2009
EN 13956:2012
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 3
EN 13859-1:2010
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proof courses (for uses subject to reaction to fire regulations)
System 3
EN 14909:2012
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 3
EN 13967:2012
EN 13969:2004
EN 13969:2004/A1:2006
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 1
EN 13162:2012
EN 13162:2012+A1:2015
EN 13163:2012
EN 13163:2012+A1:2015
EN 13164:2012
EN 13164:2012+A1:2015
EN 13165:2012
EN 13165:2012+A1:2015
EN 13165:2012+A2:2016
EN 13166:2012
EN 13166:2012+A1:2015
EN 13166:2012+A2:2016
EN 13167:2012
EN 13167:2012+A1:2015
EN 13168:2012
EN 13168:2012+A1:2015
EN 13169:2012
EN 13169:2012+A1:2015
EN 13170:2012
EN 13170:2012+A1:2015
EN 13171:2012
EN 13171:2012+A1:2015
EN 14303:2009+A1:2013
EN 14304:2009+A1:2013
EN 14305:2009+A1:2013
EN 14306:2009+A1:2013
EN 14307:2009+A1:2013
EN 14308:2009+A1:2013
EN 14309:2009+A1:2013
EN 14313:2009+A1:2013
EN 14314:2009+A1:2013
EN 14315-1:2013
EN 14318-1:2013
EN 14933:2007
EN 14934:2007
Product Certification Body
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13162:2012
EN 13162:2012+A1:2015
EN 13163:2012
EN 13163:2012+A1:2015
EN 13164:2012
EN 13164:2012+A1:2015
EN 13165:2012
EN 13165:2012+A1:2015
EN 13165:2012+A2:2016
EN 13166:2012
EN 13166:2012+A1:2015
EN 13166:2012+A2:2016
EN 13167:2012
EN 13167:2012+A1:2015
EN 13168:2012
EN 13168:2012+A1:2015
EN 13169:2012
EN 13169:2012+A1:2015
EN 13170:2012
EN 13170:2012+A1:2015
EN 13171:2012
EN 13171:2012+A1:2015
EN 14303:2009+A1:2013
EN 14304:2009+A1:2013
EN 14305:2009+A1:2013
EN 14306:2009+A1:2013
EN 14307:2009+A1:2013
EN 14308:2009+A1:2013
EN 14309:2009+A1:2013
EN 14313:2009+A1:2013
EN 14314:2009+A1:2013
EN 14315-1:2013
EN 14316-1:2004
EN 14317-1:2004
EN 14318-1:2013
EN 14933:2007
EN 14934:2007
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
System 3
EN 14351-1:2006+A1:2010
EN 14351-1:2006+A2:2016
Testing Laboratory
2011/284/EU Power, control and communication cables (1/3) :
• Power, control and communication cables (for uses subject to regulations on reaction to fire)
System 1+
EN 50575:2014/A1:2016(*)
Product Certification Body
2011/284/EU Power, control and communication cables (1/3) :
• Power, control and communication cables (for uses subject to regulations on reaction to fire)
System 3
EN 50575:2014+A1:2016(*)
Testing Laboratory
(*) Use of facilities outside the testing laboratory of the notified body
 
Horizontal notification (CPR Annex V.3)
Essential characteristics Specification Body Function
Reaction to fire EN 13823
EN ISO 1182
EN ISO 11925-2
EN ISO 1716
EN ISO 9239-1
Testing Laboratory