Navigation path

Countries


   Infocentre

Published: 21 May 2014  
Related category(ies):
Health & life sciences  |  Success stories

 

Countries involved in the project described in the article:
Belgium  |  Czech Republic  |  Germany  |  Greece  |  Spain  |  Switzerland
Add to PDF "basket"

Shielding hospital workers from radiation

While nuclear medicine (specialty involving the application of radioactive substances in the diagnosis and treatment of disease) and interventional radiology may give doctors life-saving technology to diagnose and treat diseases, the radiation emitted from the machines and systems could lead to some risks for the doctors.

Picture the doctor and patient during MRI examination © uwimages - Fotolia.com

However, thanks to the European research project ORAMED, specific recommendations for radiation protection have been developed for staff working with nuclear medicine and in interventional radiology. Furthermore, the project team has helped produce a dosimeter to measure low dose radiation.

ORAMED research team helped improve both the safety and efficacy of the use of radiation in diagnostics and therapy through new methodologies to assess and reduce radiation exposure. The work of the project team responds to earlier research that showed how high doses of radiation could be delivered to hands and other extremities not covered with protective equipment – and that there was little systematic analysis of staff radiation exposure in nuclear medicine and interventional radiology.

“So far, we have had a poor understanding of how much radiation medical staff are exposed to when they work in this field,” comments ORAMED’s project coordinator, Filip Vanhavere, from the Belgian Nuclear Research Centre SCK-CEN. “This project lays down safe working procedures with respect to radiation protection, while also developing a specific device to measure radiation doses to the lens of the eye,” he adds.

ORAMED researchers carried out a thorough investigation of radiation exposure in European hospitals, and conducted computer simulations to identify the most important factors affecting radiation doses to the eye lens and other extremities. The team also analysed the factors that influenced radiation exposure.

Data from hand exposure during nuclear medicine interventions helped shape the practical guidelines, recommendations and training packages that eventually emerged for routine monitoring. The researchers found, for example, that the maximum level of radiation to the skin on hand was three to six times higher than what is normally measured.

“We drafted our guidelines taking into account a large database of people working in nuclear medicine. We looked at all working parameters and made a significant amount of measurements across Europe,” says Vanhavere. “Our recommendations cover methods of working and shielding the body, the time limits for exposure and basic good and bad practises,” he comments.

ORAMED’s research team had a particular focus on eye lens exposure in interventional radiology. Before the prototype dosimeter was designed by the ORAMED team, there was no suitable device for eye lens radiation monitoring, nor any conversion coefficients or calibration procedures available. “Most of the existing active personal dosimeters (APDs) were developed for nuclear industry, where the type of radiation is not the same as the one found in hospitals. These dosimeters are ineffective in detecting low energy fields,” explains Vanhavere.

ORAMED project is expected to help improve radiation protection standards for medical staff. “The practical guidelines that have been developed will be used in hospitals for many years to come,” says Vanhavere. “We have made an important contribution to enhancing the safety of medical staff performing these procedures, and have filled an important gap in radiation protection,” he concludes.

Project details

  • Project acronym: ORAMED
  • Participants: Belgium (Coordinator), Italy, France, Spain, Germany, Switzerland, Greece, Poland, Czech Republic
  • FP7 Proj. N° 211361
  • Total costs: € 2 445 285
  • EU contribution: € 1 839 999
  • Duration: February 2008 - January 2011

Convert article(s) to PDF

No article selected


loading


Search articles

Notes:
To restrict search results to articles in the Information Centre, i.e. this site, use this search box rather than the one at the top of the page.

After searching, you can expand the results to include the whole Research and Innovation web site, or another section of it, or all Europa, afterwards without searching again.

Please note that new content may take a few days to be indexed by the search engine and therefore to appear in the results.

Print Version
Share this article
See also

Project web site

Project information on CORDIS

Contacts
Unit A1 - External & internal communication,
Directorate-General for Research & Innovation,
European Commission
Tel : +32 2 298 45 40
  Top   Research Information Center
 
Countries