Guide to application of the Lifts Directive 95/16/EC - Index
|
Keyword |
Directive |
Guide |
|
Access to lift machinery |
Annex I - Section 1.5.2 |
§ 108 |
|
Access to the lift car |
Annex I - Section 1.2 |
§ 99 |
|
Access to the travel zone |
Annex I - Section 2.1 |
§ 113 |
|
Affixing CE-marking |
Article 10 (2) |
§ 75 |
|
Amendment of the Lifts Directive |
Article 1 (1) |
§ 19 |
|
Assessment of Notified Bodies |
Annex VII |
§ 147 |
|
Authorised representative |
Article 8 (1) |
§ 64 |
|
Building |
Article 1 (1) |
§ 17 |
|
Buffers |
Annex I - Section 3.3 |
§ 119 |
|
Cableways |
Exclusion - Article 1 (3) |
§ 17, § 22 and § 23 |
|
Call signals |
Annex I - Section 1.6.3 |
§ 111 |
|
Car |
Article 1 (2) |
§ 22 |
|
Car doors |
Annex I - Section 3.1 |
§ 116 |
|
Carrier |
Article 1 (1) |
§ 19 |
|
CE-marking |
Recital N° 7 |
§ 11 |
|
CEN |
Article 5 (2) |
§ 52 |
|
Citations |
Citations |
§ 1 |
|
Comitology |
Recital N° 11 |
§ 15 |
|
Communication with a rescue service |
Annex I - Section 4.5 |
§ 126 |
|
Conformity assessment - safety components |
Article 8 (1) |
§ 64 and § 65 |
|
Conformity assessment - lifts |
Article 8 (2) |
§ 67 |
|
Conformity to type |
Annex XI |
§ 151 |
|
Controls |
Annex I - Section 1.6.1 |
§ 109 |
|
Construction |
Article 1 (1) |
§ 17 |
|
Construction products |
Recital N° 10 |
§ 14 |
|
Construction site hoists - exclusion |
Article 1 (3) |
§ 23 |
|
Coordination of Notified Bodies |
Article 9 |
§ 73 |
|
Counterweight |
Annex I - Section 4.3 |
§ 124 |
|
Crushing risk - doors |
Annex I - Section 4.1 |
§ 121 |
|
Crushing risk - extreme positions of the car |
Annex I - Section 2.2 |
§ 114 and § 115 |
|
Demonstrations |
Article 2 (5) |
§ 42 |
|
Design inspection |
Annex XIII |
§ 155 |
|
Design phase - lifts |
Article 8 (2) |
§ 67 |
|
Design phase - safety components |
Article 8 (1) |
§ 65 |
|
Disabled people |
Annex I - Section 1.2 |
§ 99 and § 100 |
|
Documentation |
Annex I - Section 6.2 |
§ 135 |
|
EC Declaration of conformity |
Article 5 (1) |
§ 47 |
|
EC Type examination |
Annex V A |
§ 144 |
|
Electrical hazards |
Article 1 (5) |
§ 32 |
|
Electrical equipment |
Annex I - Section 1.6.4 |
§ 112 |
|
Electric safety devices |
Annex IV |
§ 143 |
|
Electromagnetic compatibility |
Article 1 (5) |
§ 31 |
|
Emergency lighting |
Annex I - Section 4.8 |
§ 129 |
|
Essential health and safety requirements |
Article 3 (1) |
§ 43 and § 44 |
|
Evacuation of trapped persons |
Annex I - Section 4.4 |
§ 125 |
|
Exclusions |
Article 1 (3) |
§ 23 |
|
Exhibitions |
Article 2 (5) |
§ 42 |
|
Existing buildings |
Article 1 (1) |
§ 17 |
|
Existing lifts |
Recital N° 5 |
§ 8 and § 9 |
|
Final inspection |
Annex VI |
§ 146 |
|
Fire extinguisher systems |
Article 2 (3) |
§ 38 |
|
Firefighters' lifts |
Annex I - Section 4.10 |
§ 131 |
|
Fire resistance of landing doors |
Annex I - Section 4.2 |
§ 122 and § 123 |
|
Free fall |
Annex I - Sections 3.2 and 3.4 |
§ 118 and § 120 |
|
Free movement |
Citations |
§ 2 |
|
Free space or refuge |
Annex I - Section 2.2 |
§ 114 and § 115 |
|
Friction pulleys |
Annex I - Section 1.4.4 |
§ 106 |
|
Full quality assurance - lifts |
Annex XIII |
§ 153 to § 157 |
|
Full quality assurance - safety components |
Annex IX |
§ 149 |
|
Goods only lifts |
Article 1 (2) |
§ 22 |
|
Guidance |
Article 6 (2) |
§ 56 |
|
Guides |
Article 1 (1) |
§ 17 |
|
Hazards |
Annex I - Preliminary remark 1 |
§ 86 |
|
Health and safety of workers |
Article 2 (4) |
§ 40 |
|
Harmonised standards |
Recital N° 8 |
§ 12 |
|
Headroom |
Annex I - Section 2.2 |
§ 114 and § 115 |
|
Implementation |
Article 15 |
§ 82 |
|
Inclined lifts |
Article 1 (2) |
§ 22 |
|
Information |
Article 12 |
§ 79 |
|
Inspection in service |
Article 2 (4) |
§ 39 |
|
Installation phase |
Article 8 (2) |
§ 67 |
|
Installer |
Article 1 (4) |
§ 24 |
|
Installer's plate |
Annex I - Section 5.1 |
§ 132 |
|
Instructions - lifts |
Annex I - Section 6.2 |
§ 135 |
|
Instructions - safety components |
Annex I - Section 6.1 |
§ 134 |
|
Irregular CE-marking |
Article 10 (4) |
§ 77 |
|
Kit |
Article 2 (2) |
§ 36 |
|
Landing doors |
Annex I - Section 2.3 |
§ 1156 |
|
Legal remedies |
Article 11 |
§ 80 |
|
Lifting platforms - Machinery Directive |
Article 1 (1) |
§ 18 |
|
Lift machinery |
Annex I - Section 1.5.1 |
§ 107 |
|
Lifts |
Article 1 (1) |
§ 17 |
|
Lifts ADCO |
Article 2 (1) |
§ 35 |
|
Lifts Committee |
Articles 6 (3) and 6 (4) |
§ 57 |
|
Lifts in service |
Article 2 (4) |
§ 39 to § 41 |
|
Lifts Working Group |
Articles 6 (3) and 6 (4) |
§ 58 |
|
Lifts Committee |
Recital N° 11 |
§ 15 |
|
Lighting |
Annex I - Section 4.8 |
§ 129 |
|
Loading control |
Annex I - Section 1.4.1 |
§ 103 |
|
Locking devices for landing doors |
Annex I - Section 2.3 |
§ 116 |
|
Logbook |
Annex I - Section 6.2 |
§ 135 |
|
Low Voltage Directive |
Article 1 (5) |
§ 32 |
|
Machine room-less lifts |
Annex I - Section 1.5.2 |
§ 108 |
|
Machinery Directive |
Article 1 (1) |
§ 18 and § 19 |
|
Machinery standards |
Annex I - Section 1.1 |
§ 97 |
|
Machinery spaces |
Annex I - Section 1.5.2 |
§ 108 |
|
Maintenance |
Article 2 (4) |
§ 39 |
|
Major modifications |
Article 2 (4) |
§ 41 |
|
Manufacturer - safety components |
Article 1 (4) |
§ 28 |
|
Market surveillance |
Article 2 (1) |
§ 34 |
|
Marking |
Annex I - Section 5.1 |
§ 132 |
|
Means of transport - exclusion |
Article 1 (3) |
§ 23 |
|
Member States |
Article 15 |
§ 82 |
|
Military or police purposes - exclusion |
Article 1 (3) |
§ 23 |
|
Mine winding gear - exclusion |
Article 1 (3) |
§ 23 |
|
Misleading markings |
Article 10 (3) |
§ 76 |
|
Model lift |
Article 1 (4) |
§ 29 |
|
Modules |
Recital N° 6 |
§ 10 |
|
Motivation of decisions |
Article 11 |
§ 80 |
|
Moving parts |
Annex I - Section 1.1 |
§ 95 |
|
NANDO |
Article 9 |
§ 71 and § 72 |
|
National standards |
Article 5 (1) |
§ 48 |
|
New Approach |
Recital N° 2 |
§ 5 |
|
New buildings |
Article 1 (1) |
§ 17 |
|
Notification |
Article 9 |
§ 72 |
|
Notified Bodies |
Article 9 |
§ 71 to § 73 |
|
Overspeed governor (limitation device) |
Annex I - Section 1.4.2 |
§ 104 |
|
Periodic inspection |
Article 2 (4) |
§ 39 |
|
Pit |
Annex I - Section 2.2 |
§ 114, § 115 |
|
Placing on the market - lifts |
Article 1 (4) |
§ 25 |
|
Placing on the market - safety components |
Article 1 (4) |
§ 26 |
|
Presumption of conformity |
Article 5 (2) |
§ 50 |
|
Principles of safety integration |
Annex I - Section 1.1 |
§ 96 |
|
Production phase |
Article 8 (1) |
§ 65 |
|
Production quality assurance |
Annex XIV |
§ 158 |
|
Product quality assurance - lifts |
Annex XII |
§ 152 |
|
Product quality assurance - safety components |
Annex VIII |
§ 148 |
|
Publication - harmonised standards |
Article 5 (2) |
§ 53 |
|
Recitals |
Recitals |
§ 3 to § 15 |
|
Rack and pinion trains - exclusion |
Article 1 (3) |
§ 23 |
|
Recommendations for use |
Article 9 |
§ 73 |
|
Refuge |
Annex I - Section 2.2 |
§ 114, § 115 |
|
Release of trapped persons |
Annex I - Section 4.4 |
§ 125 |
|
Remote alarm |
Annex I - Section 4.5 |
§ 126 |
|
Repeal of superseded Directives |
Recital N° 4 |
§ 7 |
|
Rescue of trapped persons |
Annex I - Section 4.4 |
§ 125 |
|
Review of the Lifts Directive |
Article 16 |
§ 83 |
|
Revised Machinery Directive |
Article 1 (1) |
§ 19 |
|
Risk assessment |
Annex I - Preliminary remark 3 |
§ 89 |
|
Safeguard clause |
Article 7 |
§ 59 to § 62 |
|
Safeguard procedure |
Article 7 |
§ 62 |
|
Safety components |
Article 1 (1) |
§ 20 and § 21 |
|
Safety gear |
Annex I - Section 3.2 |
§ 118 |
|
Safety of lifts |
Citations |
§ 2 |
|
Scope |
Article 1 (1) |
§ 16 to § 21 |
|
Shaft - fittings |
Article 2 (3) |
§ 37 and § 38 |
|
Shock absorbers |
Annex I - Section 3.3 |
§ 119 |
|
Speed monitoring and limiting |
Annex I - Section 1.4.3 |
§ 105 |
|
State of the art |
Article 5 (2) |
§ 51 |
|
Stopping accuracy |
Annex I - Section 1.1 |
§ 95 |
|
Suspension and support |
Annex I - Section 1.3 |
§ 102 |
|
Temperature in machinery spaces |
Annex I - Section 4.6 |
§ 127 |
|
Theatre elevators - exclusion |
Article 1 (3) |
§ 23 |
|
Traction drive |
Annex I - Section 1.4.4 |
§ 106 |
|
Trade fairs |
Article 2 (5) | |
|
Transitional period |
Recital N° 9 |
§ 42 |
|
Travel zone |
Annex I - Section 2.1 |
§ 13 |
|
Two-way means of communication |
Annex I - Section 4.5 |
§ 113 § 126 |
|
Uncontrolled upward movement |
Annex I - Sections 3.2 and 3.4 |
§ 118 and § 1200 § 141 |
|
Unit verification |
Annex X |
§ 150 |
|
Ventilation |
Annex I - Section 4.7 |
§ 128 |
|
Well |
Article 2 (3) |
§ 37 |




