Navigation path


Notification

Found : 34
  Body (History):

STAATLICHE MATERIALPRÜFUNGSANSTALT DARMSTADT
Grafenstrasse 2
64283 DARMSTADT
Country : Germany

Phone : +49 (0) 6151 162241
Fax : +49 (0) 6151 166046

Email : stagge@mpa-iwf.tu-darmstadt.de
Website : -

Notified Body number : 1343

Version(s): 1 2 3 4

Last update : 08/09/2006
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products (History)
Last update : 11/01/2011                 Version(s): 1 2 3 4 5 6 7 8 9

Decision Product family, product /Intended use AoC system Technical specification Body function
96/581/EC Geotextiles (1/2) :
• Geosynthetics (membranes and textiles), geotextiles, geocomposites, geogrids, geomembranes and geonets used: for reinforcement (in roads, railways, foundations and walls, drainage systems, erosion control, reservoirs and dams, canals, tunnels and underground structures, liquid waste disposal or containment, for solid waste storage or waste disposal)
System 2+
EN 13361:2004
EN 13361:2004/A1:2006
EN 13362:2005
EN 13491:2004
EN 13491:2004/A1:2006
EN 13492:2004
EN 13492:2004/A1:2006
EN 13493:2005
FPC Certification Body
Inspection Body
96/581/EC Geotextiles (1/2) :
• Geosynthetics (membranes and textiles), geotextiles, geocomposites, geogrids, geomembranes and geonets used: for drainage and/or filtration (in roads, railways, foundations and walls, drainage systems, erosion control, reservoirs and dams, canals, tunnels and underground structures, liquid waste disposal or containment, for solid waste storage or waste disposal)
• Geosynthetics (membranes and textiles), geotextiles, geocomposites, geogrids, geomembranes and geonets used: as protective layer (in roads, railways, foundations and walls, drainage systems, erosion control, reservoirs and dams, canals, tunnels and underground structures, liquid waste disposal or containment, for solid waste storage or waste disposal)
System 2+
EN 13361:2004
EN 13361:2004/A1:2006
EN 13362:2005
EN 13491:2004
EN 13491:2004/A1:2006
EN 13492:2004
EN 13492:2004/A1:2006
EN 13493:2005
FPC Certification Body
Inspection Body
96/581/EC Geotextiles (1/2) :
• Geosynthetics (membranes and textiles), geotextiles, geocomposites, geogrids, geomembranes and geonets used: as fluid or gas barriers (in roads, railways, foundations and walls, drainage systems, erosion control, reservoirs and dams, canals, tunnels and underground structures, liquid waste disposal or containment, for solid waste storage or waste disposal)
System 2+
EN 13361:2004
EN 13361:2004/A1:2006
EN 13362:2005
EN 13491:2004
EN 13491:2004/A1:2006
EN 13492:2004
EN 13492:2004/A1:2006
EN 13493:2005
EN 15382:2008
FPC Certification Body
Inspection Body
96/582/EC Structural sealant glazing kits of types (curtain walling) :
• Structural sealant glazing kits, Types II and IV (for external walls and roofs)
System 1
ETAG 002 - 1
ETAG 002 - 2
ETAG 002 - 3
Product Certification Body
Inspection Body
Testing Laboratory
96/582/EC Structural sealant glazing kits of types (curtain walling) :
• Structural sealant glazing kits, Types I and III (for external walls and roofs)
System 2+
ETAG 002 - 1
ETAG 002 - 2
ETAG 002 - 3
FPC Certification Body
Inspection Body
97/740/EC Masonry and related products (1/3) :
• Factory-made, designed masonry mortars (in walls, columns and partitions)
System 2+
EN 998-2:2003
EN 998-2:2010
FPC Certification Body
Inspection Body
97/740/EC Masonry and related products (1/3) :
• Masonry units category I (in walls, columns and partitions)
System 2+
EN 771-1:2003
EN 771-1:2003/A1:2005
EN 771-2:2003
EN 771-2:2003/A1:2005
EN 771-3:2003
EN 771-3:2003/A1:2005
EN 771-4:2003
EN 771-4:2003/A1:2005
EN 771-5:2003
EN 771-5:2003/A1:2005
FPC Certification Body
Inspection Body
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 1
EN 13813:2002
Product Certification Body
Inspection Body
98/143/EC Systems of mechanically fastened flexible roof waterproofing membranes (1/1) :
• Systems of mechanically fastened flexible roof waterproofing membranes including the system of fastening, jointing and edging, and sometimes thermal insulation, limited to continuous watertight systems based on flexible sheets (for roof waterproofing)
System 2+
ETAG 006
FPC Certification Body
Inspection Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Aggregates and fillers for concrete, mortar and grout (in buildings, roads and other civil engineering work)
System 2+
EN 12620:2002+A1:2008
EN 13043:2002
EN 13043:2002/AC:2004
EN 13055-1:2002
EN 13055-1:2002/AC:2004
EN 13139:2002
EN 13139:2002/AC:2004
FPC Certification Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Aggregates for bituminous mixtures and surface treatments (for roads and other civil engineering works)
System 2+
EN 13043:2002
EN 13043:2002/AC:2004
FPC Certification Body
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (1/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for use in roofs and roof finishes)
System 3
ETAG 010
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (3/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
System 1
ETAG 010
Product Certification Body
Inspection Body
99/90/EC Membranes (1/3) :
• Roof sheets (in buildings)
System 2+
EN 13707:2004+A2:2009
EN 13956:2005
EN 13956:2005/AC:2006
FPC Certification Body
Inspection Body
99/90/EC Membranes (1/3) :
• Damp proofing sheets (in buildings)
System 2+
EN 13967:2004
EN 13967:2004/A1:2006
EN 13969:2004
EN 13969:2004/A1:2006
FPC Certification Body
Inspection Body
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 1
EN 13859-1:2005+A1:2008
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2004
EN 13984:2004/A1:2006
FPC Certification Body
Inspection Body
Product Certification Body
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 1
EN 13707:2004+A2:2009
EN 13956:2005
EN 13956:2005/AC:2006
FPC Certification Body
Inspection Body
Product Certification Body
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 1
EN 13859-2:2004+A1:2008
EN 13859-2:2010
FPC Certification Body
Inspection Body
Product Certification Body
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 1
EN 13967:2004
EN 13967:2004/A1:2006
EN 13969:2004
EN 13969:2004/A1:2006
FPC Certification Body
Inspection Body
Product Certification Body
99/91/EC Thermal insulating products (1/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (any)
System 3
EN 13165:2008
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13165:2008
Testing Laboratory
99/94/EC Precast normal/lightweight/autoclaved aerated concrete products (1/1) :
• Precast normal/lightweight/autoclaved aerated concrete products (for structural use)
System 2+
EN 13978-1:2005
EN 1520:2002
EN 1520:2002/AC:2003
FPC Certification Body
Inspection Body
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1096-4:2004
EN 12150-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Insulating glass units (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Flat or curved glass panels (for uses subject to reaction to fire regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Insulating glass units (for uses subject to reaction to fire regulations)
System 3
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Flat or curved glass panels (for uses subject to external fire performance regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Insulating glass units (for uses subject to external fire performance regulations)
System 3
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Flat or curved glass panels (for use as anti-bullet, or anti-explosion glazing)
System 1
EN 1096-4:2004
EN 12150-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Flat or curved glass panels (for other uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Insulating glass units (for use as anti-bullet, or anti-explosion glazing)
System 1
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Insulating glass units (for other uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) :
• Flat or curved glass panels (specially treated) (for uses relating to energy conservation and/or noise reduction)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) :
• Insulating glass units (for uses relating to energy conservation and/or noise reduction)
System 3
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
Testing Laboratory
Set page to normal font size Increase font size by 200 percentprint this page