Navigation path


Notification

Found : 126
  Body :

Centre Scientifique et Technique du Bâtiment (CSTB)
84, avenue Jean Jaurès
Champs-sur-Marne F-77447 Marne-la-Vallée Cedex 2
Country : France

Phone : +33 (0)1 64 68 88 89
Fax : +33 (0)1 64 68 88 92

Email : yannick.lemoigne@cstb.fr
Website : www.cstb.fr

Notified Body number : 0679

Version(s): 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Last update : 25/02/2010
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products (History)
Last update : 18/02/2009                 Version(s): 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

Decision Product family, product /Intended use AoC system Technical specification Body function
95/467/EC Chimneys, flues and specific products (1/1) :
• Prefabricated chimneys (storey height elements), flue liners (elements or blocks), multi-shell chimney (elements or blocks), single walled chimneys and attached chimneys (chimneys)
System 2+
EN 12446:2003
EN 13063-1:2005+A1:2007
EN 13069:2005
EN 13084-5:2005
EN 13084-5:2005/AC:2006
EN 13084-7:2005
EN 14471:2005
EN 1457:1999/A1:2002
EN 1457:1999/A1:2002/AC:2007
EN 1457:1999/AC:2006
EN 1806:2006
EN 1856-1:2003
EN 1856-1:2003/A1:2006
EN 1856-2:2004
EN 1857:2003
EN 1857:2003/AC:2005
EN 1857:2003/AC:2007
EN 1858:2003
Inspection Body
95/467/EC Gypsum products (1/4) :
• Plasterboards and ceiling elements with thin laminations, fibrous gypsum boards, fibrous gypsum plaster casts, and composite panels (laminates), in which the incorporated material is placed on a face susceptible to be explosed to fire, including relevant ancillary products (in walls, partitions or ceilings (or lining thereof) subject to reaction to fire requirements)
System 1
EN 13658-1:2005
EN 13658-2:2005
EN 13815:2006
EN 13950:2005
EN 13963:2005
EN 13963:2005/AC:2006
EN 14190:2005
EN 14209:2005
EN 14496:2005
EN 520:2004
ETA-03/0050 Renewal
Product Certification Body
95/467/EC Gypsum products (1/4) :
• Plasterboards and ceiling elements with thin laminations, fibrous gypsum boards, fibrous gypsum plaster casts, and composite panels (laminates), in which the incorporated material is placed on a face susceptible to be explosed to fire, including relevant ancillary products (in walls, partitions or ceilings (or lining thereof) subject to reaction to fire requirements)
System 3
EN 13658-1:2005
EN 13658-2:2005
EN 13815:2006
EN 13950:2005
EN 13963:2005
EN 13963:2005/AC:2006
EN 14190:2005
EN 14209:2005
EN 14496:2005
EN 520:2004
ETA-03/0050 Renewal
Testing Laboratory
95/467/EC Gypsum products (2/4) :
• Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings)
System 3
EN 12859:2001
EN 12859:2001/A1:2004
EN 12860:2001
Testing Laboratory
96/577/EC Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) :
• Smoke and heat exhaust ventilation systems-kits (fire safety)
System 1
EN 12101-3:2002
EN 12101-3:2002/AC:2005
Product Certification Body
96/577/EC Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) :
• Fire hydrants (fire safety)
System 1
EN 14339:2005
EN 14384:2005
Product Certification Body
96/579/EC Circulation fixtures (1/2) :
• Road lighting columns (for circulation areas)
System 1
EN 40-4:2005
EN 40-4:2005/AC:2006
FPC Certification Body
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 1
EN 13830:2003
Product Certification Body
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
• Curtain wall kits (as external walls not subject to reaction to fire requirements)
System 3
EN 13830:2003
Testing Laboratory
96/582/EC Metal anchors for use in concrete (mechanical fasteners) :
• Metal anchors for use in concrete (heavy-duty type) (for fixing and/or supporting concrete structural elements or heavy units such as cladding and suspended ceilings)
System 1
ETAG 001 - 1
ETAG 001 - 2
ETAG 001 - 3
ETAG 001 - 4
ETAG 001 - 5
Product Certification Body
96/582/EC Structural sealant glazing kits of types (curtain walling) :
• Structural sealant glazing kits, Types I and III (for external walls and roofs)
System 2+
ETAG 002 - 1
ETAG 002 - 2
ETAG 002 - 3
Inspection Body
96/582/EC Structural sealant glazing kits of types (curtain walling) :
• Structural sealant glazing kits, Types II and IV (for external walls and roofs)
System 1
ETAG 002 - 1
ETAG 002 - 2
ETAG 002 - 3
Product Certification Body
97/161/EC Metal anchors for use in concrete for fixing lightweight systems (1/1) :
• Metal anchors for use in concrete (light-duty type) (for use in reduntant systems for fixing and/or supporting to concrete elements such as lightweight suspended ceilings, as well as installations)
System 2+
ETAG 001 - 6
Inspection Body
97/176/EC Structural timber products (1/3) :
• Solid structural timber products; Kits (trusses, floors, walls, roofs, frames) (bridges, railtracks and buildings)
System 1
EN 14374:2004
Product Certification Body
97/176/EC Structural timber products (1/3) :
• Solid structural timber products: Elements (bridge elements, truss elements, sleepers, floor elements, wall elements, roof elements such as beams, arches, joists, rafters, columns, poles, piles) (bridges, railtracks and buildings)
System 2+
EN 14081-1:2005
EN 14250:2004
ETA-04/0013 Renewal
ETA-06/0138
Inspection Body
97/176/EC Structural timber products (2/3) :
• Structural glued laminated products and other glued timber products: Kits (trusses, floors, walls, roofs, frames) (for bridges and buildings)
System 1
EN 14080:2005
Product Certification Body
97/176/EC Structural timber products (2/3) :
• Structural glued laminated products and other glued timber products: Elements (bridge elements, truss elements, floor elements, wall elements, roof elements such as beams, arches, joists, rafters, columns, poles, piles) (for bridges and buildings)
System 1
EN 14080:2005
EN 14374:2004
ETA-06/0138
Product Certification Body
97/463/EC Plastic anchors for use in concrete and masonry (1/1) :
• Plastic anchors for use in concrete and masonry (for use in systems, such as facade systems, for fixing or supporting elements which contribute to the stability of the systems)
System 2+
ETAG 001 - 6
ETAG 014
Inspection Body
97/464/EC Waste water engineering products inside buildings (2/2) :
• Kits for waste water pumping station and effluent lifting plants (for use inside building)
System 3
EN 12050-1:2001
EN 12050-2:2000
EN 12050-3:2000
EN 12050-4:2000
Testing Laboratory
97/464/EC Waste water engineering products outside buildings (1/3) :
• Kits and elements for waste water treatment plants and on-site treatment equipment -Septic tanks (to be used outside buildings, for rain water, faecal and organic effluents)
System 3
EN 12566-1:2000/A1:2003
EN 12566-3:2005
Testing Laboratory
97/464/EC Waste water engineering products outside buildings (2/3) :
• Prefabricated drainage channel (to be used outside buildings, for waste water from buildings and civil engineering works including roads)
System 3
EN 1433:2002
EN 1433:2002/A1:2005
Testing Laboratory
97/556/EC External thermal insulation composite systems/kits with rendering (ETICS)(1/1) :
• External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)
System 1
ETAG 004
Product Certification Body
97/556/EC External thermal insulation composite systems/kits with rendering (ETICS)(1/1) :
• External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)
• External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)
System 2+
ETAG 004
Inspection Body
97/638/EC Fasteners for structural timber products (1/1) :
• Shear plates (for structural timber products)
• Nailing plates (for structural timber products)
• Punched nail plates (for structural timber products)
• Toothed-plate connectors (for structural timber products)
System 2+
ETAG 015
Inspection Body
97/740/EC Masonry and related products (1/3) :
• Factory-made, designed masonry mortars (in walls, columns and partitions)
System 2+
EN 998-2:2003
Inspection Body
97/740/EC Masonry and related products (1/3) :
• Masonry units category I (in walls, columns and partitions)
System 2+
EN 771-1:2003
EN 771-1:2003/A1:2005
EN 771-2:2003
EN 771-2:2003/A1:2005
EN 771-3:2003
EN 771-3:2003/A1:2005
EN 771-4:2003
EN 771-4:2003/A1:2005
EN 771-5:2003
EN 771-5:2003/A1:2005
EN 771-6:2005
Inspection Body
97/740/EC Masonry and related products (2/3) :
• Brackets (in walls and partitions)
• Joist hangers (in walls and partitions)
• Tension straps (in walls and partitions)
• Ties (in walls and partitions)
System 3
EN 845-1:2003
Testing Laboratory
97/740/EC Masonry and related products (2/3) :
• Lintels (in walls and partitions)
System 3
EN 845-2:2003
Testing Laboratory
97/740/EC Masonry and related products (2/3) :
• Bed joint reinforcement (in walls and partitions)
System 3
EN 845-3:2003
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 1
EN 14041:2004
EN 14041:2004/AC:2006
EN 14904:2006
Product Certification Body
97/808/EC Floorings (2/2) :
• Rigid flooring products<BR>(a) Components: paving units, tiles, mosaics, parquet, decking of mesh or sheet, floor gratings, rigid laminated floorings, wood based products (for internal uses including enclosed public transport premises)
System 3
EN 14342:2005
EN 14342:2005/AC:2007
EN 14411:2006
Testing Laboratory
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 3
EN 13813:2002
EN 14016-1:2004
Testing Laboratory
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 1
EN 13813:2002
Product Certification Body
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 3
EN 14041:2004
EN 14041:2004/AC:2006
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 3
EN 14041:2004
EN 14041:2004/AC:2006
EN 14904:2006
Testing Laboratory
98/143/EC Systems of mechanically fastened flexible roof waterproofing membranes (1/1) :
• Systems of mechanically fastened flexible roof waterproofing membranes including the system of fastening, jointing and edging, and sometimes thermal insulation, limited to continuous watertight systems based on flexible sheets (for roof waterproofing)
System 2+
ETAG 006
Inspection Body
98/213/EC Internal partition kits (1/5) :
• Internal partition kits (for uses subject to reaction to fire requirements)
System 3
ETAG 003
Testing Laboratory
98/213/EC Internal partition kits (1/5) :
• Internal partition kits (for uses subject to reaction to fire requirements)
System 1
ETAG 003
Product Certification Body
98/213/EC Internal partition kits (2/5) :
• Internal partition kits (for fire compartmentation)
System 3
ETAG 003
Testing Laboratory
98/213/EC Internal partition kits (3/5) :
• Internal partition kits (for uses subject to regulations on dangerous substances)
System 3
ETAG 003
Testing Laboratory
98/213/EC Internal partition kits (4/5) :
• Internal partition kits (for uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
ETAG 003
Testing Laboratory
98/214/EC Structural metallic products and ancillaries (1/4) :
• Structural metallic sections/profiles: hot rolled, cold formed or otherwise produced sections/profiles with various shapes (T, L, H, U, Z, I, channels, angle, hollow, tubes), flat products (plate, sheet, strip), bars, castings, forgings made of various metallic materials, unprotected or protected against corrosion by coating (to be used in metal structures or in composite metal and concrete structures)
System 2+
EN 10025-1:2004
EN 10210-1:2006
EN 10219-1:2006
EN 15088:2005
Inspection Body
98/214/EC Structural metallic products and ancillaries (4/4) :
• Structural connectors: metallic rivets, bolts (nuts and washers) and H.R. bolts (high strength friction grip bolts), studs, screws, railway fasteners (for uses in structural metallic works)
System 2+
EN 14399-1:2005
Inspection Body
98/279/EC Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1) :
• Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)
System 1
ETAG 009
Product Certification Body
98/279/EC Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1) :
• Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)
• Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: panels made of an insulating material (or a combination of an insulating material and other materials), consisting of shuttering leaves linked by spacers (for the construction of external and internal walls not subject to fire regulations, in buildings)
System 2+
ETAG 009
Inspection Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations)
System 3
EN 1304:2005
EN 490:2004
EN 490:2004/A1:2006
EN 544:2005
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Rooflights (for uses subject to reaction to fire regulations)
System 3
EN 1873:2005
ETA-04/0041
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Factory-bonded composite or sandwich panels (for uses subject to reaction to fire regulations)
System 3
ETA-04/0041
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roof windows (for uses subject to reaction to fire regulations)
System 3
EN 14351-1:2006
ETA-04/0041
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Flat and profiled sheets (for uses subject to reaction to fire regulations)
System 3
EN 14782:2006
EN 14783:2006
EN 494:2004+A3:2007
EN 534:2006
ETA-04/0041
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (3/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to external fire performance regulations)
System 3
EN 1304:2005
EN 490:2004
EN 490:2004/A1:2006
EN 544:2005
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (5/6) :
• All roof coverings, rooflights, roof windows and ancillary products (for uses subject to regulations on dangerous substances)
System 3
EN 12326-1:2004
EN 1304:2005
EN 490:2004
EN 490:2004/A1:2006
EN 544:2005
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (6/6) :
• Roof access systems, walkways and footholds (for uses other than those specified in families (1/6), (2/6), (3/6), (4/6), (5/6))
System 3
EN 12951:2004
EN 516:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (1/5) :
• Suspended ceilings (kits) (as internal or external finishes used for fire protection of ceilings)
System 3
EN 13964:2004
EN 13964:2004/A1:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (2/5) :
• Suspended ceilings (kits) (as internal or external finish in ceilings subject to safety in use requirements)
System 3
EN 13964:2004
EN 13964:2004/A1:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Coverings in roll form (as internal finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 14716:2004
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Coverings in roll form (as internal finishes in walls or ceilings subject to reaction to fire regulations)
System 3
EN 14716:2004
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations)
System 1
EN 13964:2004
EN 13964:2004/A1:2006
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations)
System 3
EN 13964:2004
EN 13964:2004/A1:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Sidings (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 14915:2006
EN 14915:2006/AC:2007
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Sidings (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 3
EN 14915:2006
EN 14915:2006/AC:2007
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (4/5) :
• Suspended ceilings (kits) (as internal or external finishes in walls or ceilings subject to regulations on dangerous substances)
System 3
EN 13964:2004
EN 13964:2004/A1:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (4/5) :
• Shingles (as internal or external finishes in walls or ceilings, as relevant, subject to regulations on dangerous substances)
System 3
EN 12467:2004
EN 12467:2004/A1:2005
EN 12467:2004/A2:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (4/5) :
• Sidings (as internal or external finishes in walls or ceilings, as relevant, subject to regulations on dangerous substances)
System 3
EN 14915:2006
EN 14915:2006/AC:2007
Testing Laboratory
98/456/EC Post-tensioning kits for the prestressing of structures (1/1) :
• Post-tensioning kits (for the prestressing of structures)
System 1+
ETAG 013
Product Certification Body
98/599/EC Liquid applied roof waterproofing kits (1/3) :
• Liquid applied roof waterproofing kits (for all roof waterproofing uses)
System 3
ETAG 005
Testing Laboratory
98/599/EC Liquid applied roof waterproofing kits (2/3) :
• Liquid applied roof waterproofing kits (for uses subject to external fire performance regulations)
System 3
ETAG 005
Testing Laboratory
98/599/EC Liquid applied roof waterproofing kits (3/3) :
• Liquid applied roof waterproofing kits (for uses subject to reaction to fire regulations)
System 1
ETAG 005
Product Certification Body
Testing Laboratory
98/599/EC Liquid applied roof waterproofing kits (3/3) :
• Liquid applied roof waterproofing kits (for uses subject to reaction to fire regulations)
System 3
ETAG 005
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (1/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for use in roofs and roof finishes)
System 3
ETAG 010
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (2/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to external fire performance regulations)
System 3
ETAG 010
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (3/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
System 1
ETAG 010
Product Certification Body
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (3/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
System 3
ETAG 010
Testing Laboratory
98/601/EC Road construction products (1/2) :
• Bituminous mixtures (for road construction and surface treatment of roads)
System 2+
EN 13108-1:2006
EN 13108-1:2006/AC:2008
EN 13108-2:2006
EN 13108-2:2006/AC:2008
EN 13108-3:2006
EN 13108-3:2006/AC:2008
EN 13108-4:2006
EN 13108-4:2006/AC:2008
EN 13108-5:2006
EN 13108-5:2006/AC:2008
EN 13108-6:2006
EN 13108-6:2006/AC:2008
EN 13108-7:2006
EN 13108-7:2006/AC:2008
Inspection Body
98/601/EC Road construction products (2/2) :
• Bituminous mixtures (for uses subject to reaction to fire regulations)
System 1
EN 13108-1:2006
EN 13108-1:2006/AC:2008
EN 13108-2:2006
EN 13108-2:2006/AC:2008
EN 13108-3:2006
EN 13108-3:2006/AC:2008
EN 13108-4:2006
EN 13108-4:2006/AC:2008
EN 13108-5:2006
EN 13108-5:2006/AC:2008
EN 13108-6:2006
EN 13108-6:2006/AC:2008
EN 13108-7:2006
EN 13108-7:2006/AC:2008
Product Certification Body
99/89/EC Prefabricated stair kits (1/2) :
• Prefabricated stair kits (for dwellings and other buildings)
System 2+
ETAG 008
Inspection Body
99/89/EC Prefabricated stair kits (2/2) :
• Prefabricated stair kits (for uses subject to reaction to fire regulations)
System 1
ETAG 008
Product Certification Body
Inspection Body
Testing Laboratory
99/89/EC Prefabricated stair kits (2/2) :
• Prefabricated stair kits (for uses subject to reaction to fire regulations)
System 3
ETAG 008
Testing Laboratory
99/90/EC Membranes (1/3) :
• Roof sheets (in buildings)
System 2+
EN 13707:2004
EN 13707:2004/A1:2006
EN 13956:2005
EN 13956:2005/AC:2006
Inspection Body
99/90/EC Membranes (1/3) :
• Damp proofing sheets (in buildings)
System 2+
EN 13967:2004
EN 13967:2004/A1:2006
EN 13969:2004
EN 13969:2004/A1:2006
ETA-03/0049 Renewal
Inspection Body
99/90/EC Membranes (1/3) :
• Water vapour control layers (in buildings)
System 3
EN 13859-1:2005
EN 13859-2:2004
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2004
EN 13984:2004/A1:2006
Testing Laboratory
99/90/EC Membranes (1/3) :
• Roof underlays (in buildings)
System 3
EN 13859-1:2005
ETA-05/0057
Testing Laboratory
99/90/EC Membranes (1/3) :
• Damp proof courses (in buildings)
System 3
EN 14909:2006
EN 14967:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proof courses (for uses subject to reaction to fire regulations)
System 1
EN 14909:2006
EN 14967:2006
Product Certification Body
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 1
EN 13967:2004
EN 13967:2004/A1:2006
EN 13969:2004
EN 13969:2004/A1:2006
ETA-03/0049 Renewal
Product Certification Body
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 1
EN 13859-1:2005
EN 13859-2:2004
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2004
EN 13984:2004/A1:2006
Product Certification Body
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 1
EN 13707:2004
EN 13707:2004/A1:2006
EN 13956:2005
EN 13956:2005/AC:2006
Product Certification Body
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 1
EN 13859-1:2005
ETA-05/0057
Product Certification Body
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 1
EN 13162:2001
EN 13162:2001/AC:2005
EN 13163:2001
EN 13163:2001/AC:2005
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13164:2001/AC:2005
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13165:2001/A2:2004
EN 13165:2001/AC:2005
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13166:2001/AC:2005
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13167:2001/AC:2005
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13168:2001/AC:2005
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13169:2001/AC:2005
EN 13170:2001
EN 13170:2001/AC:2005
EN 13171:2001
EN 13171:2001/ A1:2004
EN 13171:2001/AC:2005
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14316-1:2004
EN 14317-1:2004
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13162:2001
EN 13162:2001/AC:2005
EN 13163:2001
EN 13163:2001/AC:2005
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13164:2001/AC:2005
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13165:2001/A2:2004
EN 13165:2001/AC:2005
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13166:2001/AC:2005
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13167:2001/AC:2005
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13168:2001/AC:2005
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13169:2001/AC:2005
EN 13170:2001
EN 13170:2001/AC:2005
EN 13171:2001
EN 13171:2001/ A1:2004
EN 13171:2001/AC:2005
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14316-1:2004
EN 14317-1:2004
Testing Laboratory
99/92/EC Light composite wood-based beams and columns (1/1) :
• Light composite wood-based beams and columns (including T-beams, i.e. beam/slab combinations) (in buildings)
System 1
ETAG 011
Product Certification Body
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
System 3
EN 13241-1:2003
EN 14351-1:2006
ETA-04/0051
ETA-05/0128
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes)
System 1
EN 1125:1997/A1:2001
EN 1154:1996/A1:2002
EN 1155:1997/A1:2002
EN 1158:1997/A1:2002
EN 1158:1997/A1:2002/AC:2006
EN 12209:2003
EN 12209:2003/AC:2005
EN 179:1997/A1:2001
EN 1935:2002
EN 1935:2002/AC:2003
Product Certification Body
99/94/EC Precast normal/lightweight/autoclaved aerated concrete products (1/1) :
• Precast normal/lightweight/autoclaved aerated concrete products (for structural use)
System 2+
EN 1168:2005
EN 12839:2001
EN 12843:2004
EN 13225:2004
EN 13225:2004/AC:2006
EN 13693:2004
EN 13747:2005
EN 13747:2005/AC:2006
EN 13978-1:2005
EN 14843:2007
EN 14844:2006
EN 1520:2002
ETA-08/0005
ETA-08/0108
Inspection Body
99/455/EC Timber frame and log prefabricated building kits (1/1) :
• Timber frame and log prefabricated building kits (as defined in Annex I) (in building works)
System 1
ETAG 007
ETAG 012
Product Certification Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Fibres (for structural uses in concrete, mortar and grout)
System 1
EN 14889-1:2006
EN 14889-2:2006
Product Certification Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Fibres (for other uses in concrete, mortar and grout)
System 3
EN 14889-1:2006
EN 14889-2:2006
Testing Laboratory
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Concrete protection and repair products (for other uses in buildings and civil engineering works)
System 2+
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
EN 1504-5:2004
EN 1504-6:2006
EN 1504-7:2006
Inspection Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Additions (type I) (for concrete, mortar and grout)
System 2+
EN 12878:2005
EN 12878:2005/AC:2006
Inspection Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Admixtures (for concrete, mortar and grout)
System 2+
EN 934-2:2001
EN 934-2:2001/A1:2004
EN 934-2:2001/A2:2005
EN 934-3:2003
EN 934-3:2003/AC:2005
EN 934-4:2001
Inspection Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Additions (Type II) (for concrete, mortar and grout)
System 1+
EN 13263-1:2005
EN 450-1:2005
ETA-05/0095
ETA-05/0168
ETA-05/0213
Product Certification Body
99/469/EC Products related to concrete, mortar and grout (2/2) :
• Concrete protection and repair products (for uses subject to reaction to fire regulations)
System 1
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
EN 1504-5:2004
EN 1504-6:2006
EN 1504-7:2006
Product Certification Body
99/469/EC Products related to concrete, mortar and grout (2/2) :
• Concrete protection and repair products (for uses subject to reaction to fire regulations)
System 3
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
EN 1504-5:2004
EN 1504-6:2006
EN 1504-7:2006
Testing Laboratory
99/470/EC Construction adhesives (1/2) :
• Adhesives for tiles (for internal and external uses in buildings and other civil engineering works)
System 3
EN 12004:2007
Testing Laboratory
99/471/EC Space heating appliances (1/2) :
• Space heating appliances burning solid and liquid fuels (in buildings)
System 3
EN 12809:2001
EN 12809:2001/A1:2004
EN 12809:2001/A1:2004/AC:2006
EN 12809:2001/A1:2004/AC:2007
EN 12809:2001/AC:2006
EN 12815:2001
EN 12815:2001/A1:2004
EN 12815:2001/A1:2004/AC:2006
EN 12815:2001/A1:2004/AC:2007
EN 12815:2001/AC:2006
EN 13229:2001
EN 13229:2001/A1:2003
EN 13229:2001/A2:2004
EN 13229:2001/A2:2004/AC:2006
EN 13229:2001/A2:2004/AC:2007
EN 13229:2001/AC:2006
EN 13240:2001
EN 13240:2001/A2:2004
EN 13240:2001/A2:2004/AC:2006
EN 13240:2001/A2:2004/AC:2007
EN 13240:2001/AC:2006
EN 14037-1:2003
Calculation body
Testing Laboratory
99/472/EC Pipes, tanks and ancillaries not in contact with water intended for human consumption (1/5) :
• Fittings, adhesives, joints, joint sealings and gaskets (in installations for the transport/distribution/ storage of gas/fuel intended for the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building)
System 3
EN 682:2002
Testing Laboratory
99/472/EC Pipes, tanks and ancillaries not in contact with water intended for human consumption (1/5) :
• Pipes (in installations for the transport/distribution/ storage of gas/fuel intended for the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building)
System 3
EN 1057:2006
Testing Laboratory
99/472/EC Pipes, tanks and ancillaries not in contact with water intended for human consumption (1/5) :
• tanks (in installations for the transport/distribution/ storage of gas/fuel intended for the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building)
System 3
EN 12285-2:2005
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Insulating glass units (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1279-5:2005
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Insulating glass units (for uses subject to reaction to fire regulations)
System 3
EN 1279-5:2005
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Flat or curved glass panels (for uses subject to reaction to fire regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Insulating glass units (for uses subject to external fire performance regulations)
System 3
EN 1279-5:2005
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Flat or curved glass panels (for uses subject to external fire performance regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Insulating glass units (for use as anti-bullet, or anti-explosion glazing)
System 1
EN 1279-5:2005
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Insulating glass units (for other uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
EN 1279-5:2005
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Flat or curved glass panels (for other uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Flat or curved glass panels (for use as anti-bullet, or anti-explosion glazing)
System 1
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) :
• Insulating glass units (for uses relating to energy conservation and/or noise reduction)
System 3
EN 1279-5:2005
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) :
• Flat or curved glass panels (specially treated) (for uses relating to energy conservation and/or noise reduction)
System 3
EN 10224:2002
EN 10224:2002/A1:2005
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (1/6) :
• Self-supporting composite lightweight panels (for uses contributing to stiffening the structure)
System 3
ETAG 016 - 1
ETAG 016 - 2
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (2/6) :
• Self-supporting composite lightweight panels (for uses subject to resistance to fire regulations (eg fire compartmentation))
System 3
ETAG 016 - 1
ETAG 016 - 2
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (3/6) :
• Self-supporting composite lightweight panels (for uses subject to reaction to fire regulations)
System 3
ETAG 016 - 1
ETAG 016 - 2
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (3/6) :
• Self-supporting composite lightweight panels (for uses subject to reaction to fire regulations)
System 1
ETAG 016 - 1
ETAG 016 - 2
Product Certification Body
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (4/6) :
• Self-supporting composite lightweight panels (for uses subject to external fire performance regulations)
System 3
ETAG 016 - 1
ETAG 016 - 2
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (5/6) :
• Self-supporting composite lightweight panels (for uses subject to regulations on dangerous substances)
System 3
ETAG 016 - 1
ETAG 016 - 2
Testing Laboratory