Navigation path


Notification

Found : 37
  Body (History):

ITC-CNR ISTITUTO PER LA TECNOLOGIA DELLE COSTRUZIONI
Via Lombardia, 49
20098 - San Giuliano Milanese (MI)
Country : Italy

Phone : +39 02 9806440
Fax : +39 02 98280088

Email : info@itc.cnr.it
Website : www.itc.cnr.it

Notified Body number : 0970

Version(s): 1 2 3

Last update : 26/04/2007
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products (History)
Last update : 02/12/2005                 Version(s): 1 2 3 4 5 6 7

Decision Product family, product /Intended use AoC system Technical specification Body function
95/467/EC Structural bearings (1/1) :
• Structural bearings (in buildings and civil engineering works where requirements on individual beraings are not critical)
System 3
EN 1337-7:2000
Testing Laboratory
95/467/EC Structural bearings (1/1) :
• Structural bearings (in buildings and civil engineering works where requirements on individual bearings are critical)
System 1
EN 1337-7:2000
Product Certification Body
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 1
EN 13830:2003
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
• Curtain wall kits (as external walls not subject to reaction to fire requirements)
System 3
EN 13830:2003
Testing Laboratory
96/582/EC Structural sealant glazing kits of types (curtain walling) :
• Structural sealant glazing kits, Types II and IV (for external walls and roofs)
System 1
ETAG 002 - 1
ETAG 002 - 2
ETAG 002 - 3
Product Certification Body
Inspection Body
Testing Laboratory
96/582/EC Structural sealant glazing kits of types (curtain walling) :
• Structural sealant glazing kits, Types I and III (for external walls and roofs)
System 2+
ETAG 002 - 1
ETAG 002 - 2
ETAG 002 - 3
Inspection Body
97/161/EC Metal anchors for use in concrete for fixing lightweight systems (1/1) :
• Metal anchors for use in concrete (light-duty type) (for use in reduntant systems for fixing and/or supporting to concrete elements such as lightweight suspended ceilings, as well as installations)
System 2+
ETAG 001 - 6
FPC Certification Body
97/463/EC Plastic anchors for use in concrete and masonry (1/1) :
• Plastic anchors for use in concrete and masonry (for use in systems, such as facade systems, for fixing or supporting elements which contribute to the stability of the systems)
System 2+
ETAG 001 - 6
ETAG 014
FPC Certification Body
Inspection Body
97/555/EC Cements, building limes and other hydraulic binders :
• Common cements, including:<BR>-Portland cement,<BR>-Portland composite cements: Portland-slag cement, Portland-silica fume cement, Portland-pozzolana cement, Portland-fly ash cement, Portland-burnt shale cement, Portland-limestone cement, Portland composite cement,<BR>-Blastfurnace cements,<BR>-Pozzolanic cements,<BR>-Composite cements (preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products)
System 1+
EN 14216:2004
EN 197-1:2000
EN 197-1:2000/ A1:2004
EN 197-4:2004
Product Certification Body
Inspection Body
Testing Laboratory
97/556/EC External thermal insulation composite systems/kits with rendering (ETICS)(1/1) :
• External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)
System 1
ETAG 004
Product Certification Body
FPC Certification Body
97/556/EC External thermal insulation composite systems/kits with rendering (ETICS)(1/1) :
• External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)
• External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)
System 2+
ETAG 004
FPC Certification Body
98/143/EC Systems of mechanically fastened flexible roof waterproofing membranes (1/1) :
• Systems of mechanically fastened flexible roof waterproofing membranes including the system of fastening, jointing and edging, and sometimes thermal insulation, limited to continuous watertight systems based on flexible sheets (for roof waterproofing)
System 2+
ETAG 006
FPC Certification Body
Inspection Body
98/213/EC Internal partition kits (1/5) :
• Internal partition kits (for uses subject to reaction to fire requirements)
System 1
ETAG 003
Product Certification Body
Testing Laboratory
98/213/EC Internal partition kits (1/5) :
• Internal partition kits (for uses subject to reaction to fire requirements)
System 3
ETAG 003
Testing Laboratory
98/213/EC Internal partition kits (2/5) :
• Internal partition kits (for fire compartmentation)
System 3
ETAG 003
Testing Laboratory
98/213/EC Internal partition kits (3/5) :
• Internal partition kits (for uses subject to regulations on dangerous substances)
System 3
ETAG 003
Testing Laboratory
98/213/EC Internal partition kits (4/5) :
• Internal partition kits (for uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
ETAG 003
Testing Laboratory
98/279/EC Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1) :
• Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)
System 1
ETAG 009
Product Certification Body
FPC Certification Body
98/279/EC Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1) :
• Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)
• Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: panels made of an insulating material (or a combination of an insulating material and other materials), consisting of shuttering leaves linked by spacers (for the construction of external and internal walls not subject to fire regulations, in buildings)
System 2+
ETAG 009
FPC Certification Body
98/599/EC Liquid applied roof waterproofing kits (3/3) :
• Liquid applied roof waterproofing kits (for uses subject to reaction to fire regulations)
System 1
ETAG 005
FPC Certification Body
Inspection Body
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (1/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for use in roofs and roof finishes)
System 3
ETAG 010
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (2/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to external fire performance regulations)
System 3
ETAG 010
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (3/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
System 1
ETAG 010
Product Certification Body
Inspection Body
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (3/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
System 3
ETAG 010
Testing Laboratory
99/90/EC Membranes (1/3) :
• Roof underlays (in buildings)
System 3
EN 13859-2:2004
Testing Laboratory
99/90/EC Membranes (1/3) :
• Water vapour control layers (in buildings)
System 3
EN 13970:2004
EN 13984:2004
Testing Laboratory
99/90/EC Membranes (1/3) :
• Damp proofing sheets (in buildings)
System 2+
EN 13967:2004
EN 13969:2004
FPC Certification Body
Inspection Body
99/90/EC Membranes (1/3) :
• Roof sheets (in buildings)
System 2+
EN 13707:2004
FPC Certification Body
Inspection Body
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 1
EN 13859-2:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 3
EN 13859-2:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 1
EN 13970:2004
EN 13984:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 3
EN 13970:2004
EN 13984:2004
Testing Laboratory
99/455/EC Timber frame and log prefabricated building kits (1/1) :
• Timber frame and log prefabricated building kits (as defined in Annex I) (in building works)
System 1
ETAG 007
ETAG 012
Product Certification Body
Inspection Body
Testing Laboratory
99/470/EC Construction adhesives (1/2) :
• Adhesives for tiles (for internal and external uses in buildings and other civil engineering works)
System 3
EN 12004:2001/A1:2002
Testing Laboratory
99/470/EC Construction adhesives (2/2) :
• Adhesives for tiles (for uses subject to reaction to fire regulations)
System 1
EN 12004:2001/A1:2002
Testing Laboratory
99/470/EC Construction adhesives (2/2) :
• Adhesives for tiles (for uses subject to reaction to fire regulations)
System 3
EN 12004:2001/A1:2002
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (1/6) :
• Self-supporting composite lightweight panels (for uses contributing to stiffening the structure)
System 3
ETAG 016 - 1
ETAG 016 - 2
Testing Laboratory
Set page to normal font size Increase font size by 200 percentprint this page