Navigation path


Notification

Found : 33
  Body :

WFRGENT N.V. (WARRINGTON FIRE GENT)
Ottergemsesteenweg-Zuid 711
9000 GENT
Country : Belgium

Phone : +32:9:243 77 50
Fax : +32:9:243 77 51

Email : info@wfrgent.com
Website : www.wfrgent.com

Notified Body number : 1173

Version(s): 1 2 3 4 5 6 7 8 9 10 11 12

Last update : 21/01/2013
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products (History)
Last update : 11/04/2007                 Version(s): 1 2 3 4 5 6 7 8 9 10 11 12 13

Decision Product family, product /Intended use AoC system Technical specification Body function
95/467/EC Gypsum products (2/4) :
• Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings)
System 3
EN 12859:2001
EN 12859:2001/A1:2004
EN 12860:2001
Testing Laboratory
96/582/EC Structural sealant glazing kits of types (curtain walling) :
• Structural sealant glazing kits, Types II and IV (for external walls and roofs)
System 1
ETAG 002 - 1
ETAG 002 - 2
ETAG 002 - 3
Testing Laboratory
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external application)
System 1
EN 13986:2004
Testing Laboratory
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 1
EN 13986:2004
Testing Laboratory
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 3
EN 13986:2004
Testing Laboratory
97/740/EC Masonry and related products (2/3) :
• Lintels (in walls and partitions)
System 3
EN 845-2:2003
Testing Laboratory
98/213/EC Internal partition kits (1/5) :
• Internal partition kits (for uses subject to reaction to fire requirements)
System 1
ETAG 003
Testing Laboratory
98/213/EC Internal partition kits (1/5) :
• Internal partition kits (for uses subject to reaction to fire requirements)
System 3
ETAG 003
Testing Laboratory
98/213/EC Internal partition kits (2/5) :
• Internal partition kits (for fire compartmentation)
System 3
ETAG 003
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (1/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for use in roofs and roof finishes)
System 3
ETAG 010
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (2/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to external fire performance regulations)
System 3
ETAG 010
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (3/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
System 1
ETAG 010
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (3/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
System 3
ETAG 010
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 1
EN 13707:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 3
EN 13707:2004
Testing Laboratory
99/90/EC Membranes (3/3) :
• Roof sheets (for uses subject to external fire performance regulations)
System 3
EN 13707:2004
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 1
EN 13162:2001
EN 13163:2001
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13170:2001
EN 13171:2001
EN 13171:2001/ A1:2004
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13162:2001
EN 13163:2001
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13170:2001
EN 13171:2001
EN 13171:2001/ A1:2004
Testing Laboratory
99/92/EC Light composite wood-based beams and columns (1/1) :
• Light composite wood-based beams and columns (including T-beams, i.e. beam/slab combinations) (in buildings)
System 1
ETAG 011
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes)
System 1
EN 1125:1997/A1:2001
EN 1154:1996/A1:2002
EN 1155:1997/A1:2002
EN 1158:1997/A1:2002
EN 179:1997/A1:2001
EN 1935:2002
Testing Laboratory
99/454/EC Fire stopping, fire sealing and fire protective products (2/2) :
• Fire stopping and fire sealing products (for uses subject to reaction to fire regulations)
• Fire protective products (including coatings) (for uses subject to reaction to fire regulations)
System 1
ETAG 018 - 1
ETAG 018 - 4
Testing Laboratory
99/470/EC Construction adhesives (1/2) :
• Adhesives for tiles (for internal and external uses in buildings and other civil engineering works)
System 3
EN 12004:2001/A1:2002
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Flat or curved glass panels (for uses subject to reaction to fire regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Flat or curved glass panels (for uses subject to external fire performance regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (2/6) :
• Prefabricated wood-based load-bearing stressed skin panels (for uses subject to resistance to fire regulations (eg fire compartmentation))
System 3
ETAG 019
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (2/6) :
• Self-supporting composite lightweight panels (for uses subject to resistance to fire regulations (eg fire compartmentation))
System 3
ETAG 016 - 1
ETAG 016 - 2
ETAG 016 - 3
ETAG 016 - 4
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (3/6) :
• Prefabricated wood-based load-bearing stressed skin panels (for uses subject to reaction to fire regulations)
System 1
ETAG 019
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (3/6) :
• Prefabricated wood-based load-bearing stressed skin panels (for uses subject to reaction to fire regulations)
System 3
ETAG 019
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (3/6) :
• Self-supporting composite lightweight panels (for uses subject to reaction to fire regulations)
System 1
ETAG 016 - 1
ETAG 016 - 2
ETAG 016 - 3
ETAG 016 - 4
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (3/6) :
• Self-supporting composite lightweight panels (for uses subject to reaction to fire regulations)
System 3
ETAG 016 - 1
ETAG 016 - 2
ETAG 016 - 3
ETAG 016 - 4
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (4/6) :
• Prefabricated wood-based load-bearing stressed skin panels (for uses subject to external fire performance regulations)
System 3
ETAG 019
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (4/6) :
• Self-supporting composite lightweight panels (for uses subject to external fire performance regulations)
System 3
ETAG 016 - 1
ETAG 016 - 2
ETAG 016 - 3
ETAG 016 - 4
Testing Laboratory
Set page to normal font size Increase font size by 200 percentprint this page