Last update : 23/10/2013                 Version(s): 1 2 3 4 5

Decision Product family, product /Intended use AVCP system Technical specification Body function
95/467/EC Gypsum products (2/4) :
• Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings)
System 3
EN 12859:2011
EN 14246:2006
EN 14246:2006/AC:2007
Testing Laboratory
96/579/EC Circulation fixtures (2/2) :
• Road traffic noise reducing devices and barriers (for circulation areas)
System 3
EN 14388:2005
EN 14388:2005/AC:2008
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls not subject to reaction to fire requirements)
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 3
EN 13830:2003
Testing Laboratory
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 3
EN 13986:2004
Testing Laboratory
97/740/EC Masonry and related products (2/3) :
• Lintels (in walls and partitions)
System 3
EN 845-2:2003
EN 845-2:2013
Testing Laboratory
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 3
EN 13813:2002
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 3
EN 14041:2004
EN 14041:2004/AC:2006
EN 14904:2006
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Flat and profiled sheets (for uses subject to reaction to fire regulations)
System 3
EN 534:2006+A1:2010
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations)
System 3
EN 544:2011
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roof windows (for uses subject to reaction to fire regulations)
System 3
EN 14351-1:2006+A1:2010
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (3/6) :
• Roof windows (for uses subject to external fire performance regulations)
System 3
EN 14351-1:2006+A1:2010
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (1/5) :
• Suspended ceilings (kits) (as internal or external finishes used for fire protection of ceilings)
System 3
EN 13964:2004
EN 13964:2004/A1:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (1/5) :
• Panels (as internal or external finishes, as complete elements, used for fire protection of walls or ceilings)
System 3
EN 438-7:2005
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (2/5) :
• Suspended ceilings (kits) (as internal or external finish in ceilings subject to safety in use requirements)
System 3
EN 13964:2004
EN 13964:2004/A1:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (2/5) :
• Panels (as internal or external stiffening elements in walls or ceilings)
System 3
EN 438-7:2005
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations)
System 3
EN 13964:2004
EN 13964:2004/A1:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (4/5) :
• Panels (as internal or external finishes in walls or ceilings, as relevant, subject to regulations on dangerous substances)
System 3
EN 438-7:2005
Testing Laboratory
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Fillers for bituminous mixtures and surface treatments (for roads and other civil engineering works)
• Aggregates for bituminous mixtures and surface treatments (for roads and other civil engineering works)
• Armourstones (for hydraulic structures and other civil engineering works)
• Railway ballast (for railway works)
• Aggregates and fillers for concrete, mortar and grout (in buildings, roads and other civil engineering work)
• Aggregates for unbound and hydraulically bound mixtures (for roads and other civil engineering works)
System 2+
EN 12620:2002+A1:2008
EN 13043:2002
EN 13043:2002/AC:2004
EN 13055-1:2002
EN 13055-1:2002/AC:2004
EN 13139:2002
EN 13139:2002/AC:2004
EN 13242:2002+A1:2007
EN 13383-1:2002
EN 13383-1:2002/AC:2004
EN 13450:2002
EN 13450:2002/AC:2004
FPC Certification Body
98/601/EC Road construction products (2/2) :
• Bituminous mixtures (for uses subject to reaction to fire regulations)
System 3
EN 13108-1:2006
EN 13108-1:2006/AC:2008
EN 13108-2:2006
EN 13108-2:2006/AC:2008
EN 13108-3:2006
EN 13108-3:2006/AC:2008
EN 13108-4:2006
EN 13108-4:2006/AC:2008
EN 13108-5:2006
EN 13108-5:2006/AC:2008
EN 13108-6:2006
EN 13108-6:2006/AC:2008
EN 13108-7:2006
EN 13108-7:2006/AC:2008
Testing Laboratory
99/90/EC Membranes (1/3) :
• Damp proof courses (in buildings)
System 3
EN 14909:2012
EN 14967:2006
Testing Laboratory
99/90/EC Membranes (1/3) :
• Roof underlays (in buildings)
System 3
EN 13859-1:2010
Testing Laboratory
99/90/EC Membranes (1/3) :
• Water vapour control layers (in buildings)
System 3
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2013
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 3
EN 13967:2012
EN 13969:2004
EN 13969:2004/A1:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proof courses (for uses subject to reaction to fire regulations)
System 3
EN 14909:2012
EN 14967:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 3
EN 13859-1:2010
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 3
EN 13707:2004+A2:2009
Testing Laboratory
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 3
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2013
Testing Laboratory
99/90/EC Membranes (3/3) :
• Roof underlays (for uses subject to external fire performance regulations)
System 3
EN 13859-1:2010
Testing Laboratory
99/90/EC Membranes (3/3) :
• Roof sheets (for uses subject to external fire performance regulations)
System 3
EN 13707:2004+A2:2009
Testing Laboratory
99/91/EC Thermal insulating products (1/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (any)
System 3
EN 13162:2012
EN 13163:2012
EN 13164:2012
EN 13165:2012
EN 13166:2012
EN 13167:2012
EN 13168:2012
EN 13169:2012
EN 13170:2012
EN 13171:2012
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13162:2012
EN 13163:2012
EN 13164:2012
EN 13165:2012
EN 13166:2012
EN 13167:2012
EN 13168:2012
EN 13169:2012
EN 13170:2012
EN 13171:2012
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
System 3
EN 13241-1:2003+A1:2011
EN 14351-1:2006+A1:2010
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Windows (with or without related hardware) (any other)
System 3
EN 14351-1:2006+A1:2010
Testing Laboratory
99/469/EC Products related to concrete, mortar and grout (2/2) :
• Concrete protection and repair products (for uses subject to reaction to fire regulations)
System 3
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Flat or curved glass panels (for uses subject to reaction to fire regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005+A2:2010
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Insulating glass units (for uses subject to reaction to fire regulations)
System 3
EN 1279-5:2005+A2:2010
Testing Laboratory
2011/19/EU Sealants for non-structural use in joints in buildings and pedestrian walkways (1/2) :
• Sealants for external walls (Outdoor applications)
System 3
EN 15651-1:2012(*)
Testing Laboratory
2011/19/EU Sealants for non-structural use in joints in buildings and pedestrian walkways (1/2) :
• Sealants for sanitary joints (For uses in building construction)
System 3
EN 15651-3:2012(*)
Testing Laboratory
2011/19/EU Sealants for non-structural use in joints in buildings and pedestrian walkways (1/2) :
• Sealants for pedestrian walkways (For uses in building construction)
System 3
EN 15651-4:2012(*)
Testing Laboratory
2011/19/EU Sealants for non-structural use in joints in buildings and pedestrian walkways (1/2) :
• Sealants for glazing (For uses in building construction)
System 3
EN 15651-2:2012(*)
Testing Laboratory
2011/19/EU Sealants for non-structural use in joints in buildings and pedestrian walkways (2/2) :
• Sealants for non-structural use in joints in buildings and pedestrian walkways (for uses subject to reaction to fire regulations)
System 3
EN 15651-1:2012(*)
EN 15651-2:2012(*)
EN 15651-3:2012(*)
EN 15651-4:2012(*)
Testing Laboratory
(*) Use of facilities outside the testing laboratory of the notified body
 
Horizontal notification (CPR Annex V.3)
Essential characteristics Specification Body Function
Reaction to fire EN 13823
EN ISO 1182
EN ISO 11925-2
EN ISO 1716
EN ISO 9239-1
Testing Laboratory
Resistance to fire EN 13381-6
EN 13381-8
EN 1365-3
EN 1365-4
EN 1366-7
EN 1634-1
ENV 13381-5
ENV 13381-7
Testing Laboratory
External fire performance TS 1187
Testing Laboratory