  Body (History):

MATERIALPR├ťFUNGSAMT NORDRHEIN-WESTFALEN (MPA NRW)
Marsbruchstra├če 186
D-44287 DORTMUND
Country : Germany

Phone : +49 (0) 231 4502-0
Fax : +49 (0) 231 458549

Email : info@mpanrw.de
Website : http://www.mpanrw.de

Notified Body number : 0432

Version(s): 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Last update : 30/07/2013
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
Regulation (EU) No 305/2011 - Construction products (History)
Last update : 30/07/2013                 Version(s): 1 2

Decision Product family, product /Intended use AVCP system Technical specification Body function
95/467/EC Chimneys, flues and specific products (1/1) :
• Prefabricated chimneys (storey height elements), flue liners (elements or blocks), multi-shell chimney (elements or blocks), single walled chimneys and attached chimneys (chimneys)
System 2+
EN 12446:2011
EN 14471:2005
EN 1457-1:2012
EN 1457-2:2012
EN 14989-1:2007
EN 14989-2:2007
EN 1856-1:2009
EN 1856-2:2009
EN 1857:2010
EN 1858:2008+A1:2011
FPC Certification Body
95/467/EC Gypsum products (1/4) :
• Plasterboards and ceiling elements with thin laminations, fibrous gypsum boards, fibrous gypsum plaster casts, and composite panels (laminates), in which the incorporated material is placed on a face susceptible to be explosed to fire, including relevant ancillary products (in walls, partitions or ceilings (or lining thereof) subject to reaction to fire requirements)
System 3
EN 520:2004+A1:2009
Testing Laboratory
95/467/EC Gypsum products (2/4) :
• Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings)
System 3
EN 12859:2011
EN 12860:2001
EN 12860:2001/AC:2002
EN 520:2004+A1:2009
Testing Laboratory
95/467/EC Gypsum products (3/4) :
• Plasterboards, including relevant ancillary products (for stiffening timber-framed windload bearing walls or timber roof struss structures)
System 3
EN 520:2004+A1:2009
Testing Laboratory
95/467/EC Structural bearings (1/1) :
• Structural bearings (in buildings and civil engineering works where requirements on individual beraings are not critical)
System 3
EN 1337-3:2005
Testing Laboratory
95/467/EC Structural bearings (1/1) :
• Structural bearings (in buildings and civil engineering works where requirements on individual bearings are critical)
System 1
EN 1337-3:2005
Product Certification Body
96/577/EC Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) :
• Smoke curtains (fire safety)
System 1
EN 12101-1:2005
EN 12101-1:2005/A1:2006
Product Certification Body
96/577/EC Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) :
• Smoke and heat exhaust ventilation systems-kits (fire safety)
System 1
EN 12101-2:2003
Product Certification Body
96/577/EC Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) :
• Ducts (fire safety)
System 1
EN 12101-7:2011
Product Certification Body
96/577/EC Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) :
• Dampers (fire safety)
System 1
EN 12101-8:2011
EN 15650:2010
Product Certification Body
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external applications)
System 2+
EN 13986:2004
FPC Certification Body
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external application)
System 1
EN 13986:2004
Product Certification Body
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 3
EN 13986:2004
Testing Laboratory
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 1
EN 13986:2004
Product Certification Body
97/740/EC Masonry and related products (1/3) :
• Masonry units category I (in walls, columns and partitions)
System 2+
EN 771-1:2011
EN 771-2:2011
EN 771-3:2011
EN 771-4:2011
EN 771-5:2011
EN 771-6:2011
FPC Certification Body
97/740/EC Masonry and related products (1/3) :
• Factory-made, designed masonry mortars (in walls, columns and partitions)
System 2+
EN 998-2:2010
FPC Certification Body
97/740/EC Masonry and related products (2/3) :
• Bed joint reinforcement (in walls and partitions)
System 3
EN 845-3:2003+A1:2008
EN 845-3:2013
Testing Laboratory
97/740/EC Masonry and related products (3/3) :
• Masonry units incorporating thermal insulating materials placed on a face susceptible to be exposed to fire (in walls and partitions subject to reaction to fire regulations)
System 3
EN 15824:2009
Testing Laboratory
97/740/EC Masonry and related products (3/3) :
• Masonry units incorporating thermal insulating materials placed on a face susceptible to be exposed to fire (in walls and partitions subject to reaction to fire regulations)
System 1
EN 15824:2009
Product Certification Body
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 3
EN 13454-1:2004
EN 13813:2002
Testing Laboratory
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 1
EN 13454-1:2004
EN 13813:2002
Product Certification Body
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 3
EN 14041:2004
EN 14041:2004/AC:2006
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 1
EN 14041:2004
EN 14041:2004/AC:2006
Product Certification Body
97/808/EC Floorings (2/2) :
• Rigid flooring products<BR>(a) Components: paving units, tiles, mosaics, parquet, decking of mesh or sheet, floor gratings, rigid laminated floorings, wood based products (for internal uses including enclosed public transport premises)
System 3
EN 14342:2005+A1:2008
EN 14342:2013
Testing Laboratory
98/214/EC Structural metallic products and ancillaries (1/4) :
• Structural metallic sections/profiles: hot rolled, cold formed or otherwise produced sections/profiles with various shapes (T, L, H, U, Z, I, channels, angle, hollow, tubes), flat products (plate, sheet, strip), bars, castings, forgings made of various metallic materials, unprotected or protected against corrosion by coating (to be used in metal structures or in composite metal and concrete structures)
System 2+
EN 10025-1:2004
EN 10088-4:2009
EN 10088-5:2009
EN 10210-1:2006
EN 10219-1:2006
EN 10340:2007
EN 10340:2007/AC:2008
EN 10343:2009
EN 15088:2005
FPC Certification Body
98/214/EC Structural metallic products and ancillaries (4/4) :
• Structural connectors: metallic rivets, bolts (nuts and washers) and H.R. bolts (high strength friction grip bolts), studs, screws, railway fasteners (for uses in structural metallic works)
System 2+
EN 14399-1:2005
FPC Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (1/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to resistance to fire regulations (e.g. fire compartmentation))
System 3
EN 12326-1:2004
EN 492:2012
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (1/6) :
• Flat and profiled sheets (for uses subject to resistance to fire regulations (e.g. fire compartmentation))
System 3
EN 494:2012
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (1/6) :
• Factory-bonded composite or sandwich panels (for uses subject to resistance to fire regulations (e.g. fire compartmentation))
System 3
EN 14509:2006
EN 14509:2006/AC:2008
EN 14509:2013
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations)
System 3
EN 12326-1:2004
EN 490: 2011
EN 492:2012
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Flat and profiled sheets (for uses subject to reaction to fire regulations)
System 3
EN 494:2012
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Factory-bonded composite or sandwich panels (for uses subject to reaction to fire regulations)
System 3
EN 14509:2006
EN 14509:2006/AC:2008
EN 14509:2013
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Factory-bonded composite or sandwich panels (for uses subject to reaction to fire regulations)
System 1
EN 14509:2006
EN 14509:2006/AC:2008
EN 14509:2013
Product Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (3/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to external fire performance regulations)
System 3
EN 12326-1:2004
EN 490: 2011
EN 492:2012
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (3/6) :
• Flat and profiled sheets (for uses subject to external fire performance regulations)
System 3
EN 494:2012
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (3/6) :
• Factory-bonded composite or sandwich panels (for uses subject to external fire performance regulations)
System 3
EN 14509:2006
EN 14509:2006/AC:2008
EN 14509:2013
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (1/5) :
• Suspended ceilings (kits) (as internal or external finishes used for fire protection of ceilings)
System 3
EN 13964:2004
EN 13964:2004/A1:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Cladding slabs (as external finishes in walls or ceilings subject to reaction to fire regulations)
System 3
EN 1469:2004
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations)
System 3
EN 13964:2004
EN 13964:2004/A1:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Panels (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 3
EN 14509:2006
EN 14509:2006/AC:2008
EN 14509:2013
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Panels (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 14509:2006
EN 14509:2006/AC:2008
EN 14509:2013
Product Certification Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Aggregates and fillers for concrete, mortar and grout (in buildings, roads and other civil engineering work)
• Aggregates for unbound and hydraulically bound mixtures (for roads and other civil engineering works)
• Aggregates for bituminous mixtures and surface treatments (for roads and other civil engineering works)
• Armourstones (for hydraulic structures and other civil engineering works)
• Fillers for bituminous mixtures and surface treatments (for roads and other civil engineering works)
• Railway ballast (for railway works)
System 2+
EN 12620:2002+A1:2008
EN 13043:2002
EN 13043:2002/AC:2004
EN 13055-1:2002
EN 13055-1:2002/AC:2004
EN 13055-2:2004
EN 13139:2002
EN 13139:2002/AC:2004
EN 13242:2002+A1:2007
FPC Certification Body
99/90/EC Membranes (1/3) :
• Roof sheets (in buildings)
System 2+
EN 13707:2004+A2:2009
EN 13956:2012
FPC Certification Body
99/90/EC Membranes (1/3) :
• Roof underlays (in buildings)
System 3
EN 13859-1:2010
Testing Laboratory
99/90/EC Membranes (1/3) :
• Water vapour control layers (in buildings)
System 3
EN 13859-1:2010
EN 13859-2:2010
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2013
Testing Laboratory
99/90/EC Membranes (1/3) :
• Damp proofing sheets (in buildings)
System 2+
EN 13967:2012
FPC Certification Body
99/90/EC Membranes (1/3) :
• Damp proof courses (in buildings)
System 3
EN 14909:2012
EN 14967:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 3
EN 13707:2004+A2:2009
EN 13956:2012
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 1
EN 13707:2004+A2:2009
EN 13956:2012
Product Certification Body
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 3
EN 13859-1:2010
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 1
EN 13859-1:2010
Product Certification Body
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 3
EN 13859-1:2010
EN 13859-2:2010
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2013
Testing Laboratory
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 1
EN 13859-1:2010
EN 13859-2:2010
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2013
Product Certification Body
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 3
EN 13967:2012
EN 13969:2004
EN 13969:2004/A1:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 1
EN 13967:2012
EN 13969:2004
EN 13969:2004/A1:2006
Product Certification Body
99/90/EC Membranes (2/3) :
• Damp proof courses (for uses subject to reaction to fire regulations)
System 3
EN 14909:2012
EN 14967:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proof courses (for uses subject to reaction to fire regulations)
System 1
EN 14909:2012
EN 14967:2006
Product Certification Body
99/90/EC Membranes (3/3) :
• Roof sheets (for uses subject to external fire performance regulations)
System 3
EN 13707:2004+A2:2009
EN 13956:2012
Testing Laboratory
99/90/EC Membranes (3/3) :
• Roof underlays (for uses subject to external fire performance regulations)
System 3
EN 13859-1:2010
Testing Laboratory
99/91/EC Thermal insulating products (1/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (any)
System 3
EN 13162:2012
EN 13163:2012
EN 13164:2012
EN 13165:2012
EN 13166:2012
EN 13167:2012
EN 13168:2012
EN 13169:2012
EN 13170:2012
EN 13171:2012
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14064-1:2010
EN 14303:2009+A1:2013
EN 14304:2009+A1:2013
EN 14305:2009+A1:2013
EN 14306:2009+A1:2013
EN 14307:2009+A1:2013
EN 14308:2009+A1:2013
EN 14309:2009+A1:2013
EN 14313:2009+A1:2013
EN 14314:2009+A1:2013
EN 14316-1:2004
EN 14317-1:2004
EN 15599-1:2010
EN 15600-1:2010
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13162:2012
EN 13163:2012
EN 13164:2012
EN 13165:2012
EN 13166:2012
EN 13167:2012
EN 13168:2012
EN 13169:2012
EN 13170:2012
EN 13171:2012
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14064-1:2010
EN 14303:2009+A1:2013
EN 14304:2009+A1:2013
EN 14305:2009+A1:2013
EN 14306:2009+A1:2013
EN 14307:2009+A1:2013
EN 14308:2009+A1:2013
EN 14309:2009+A1:2013
EN 14313:2009+A1:2013
EN 14314:2009+A1:2013
EN 14316-1:2004
EN 14317-1:2004
EN 15599-1:2010
EN 15600-1:2010
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 1
EN 13162:2012
EN 13163:2012
EN 13164:2012
EN 13165:2012
EN 13166:2012
EN 13167:2012
EN 13168:2012
EN 13169:2012
EN 13170:2012
EN 13171:2012
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14064-1:2010
EN 14303:2009+A1:2013
EN 14304:2009+A1:2013
EN 14305:2009+A1:2013
EN 14306:2009+A1:2013
EN 14307:2009+A1:2013
EN 14308:2009+A1:2013
EN 14309:2009+A1:2013
EN 14313:2009+A1:2013
EN 14314:2009+A1:2013
EN 14316-1:2004
EN 14317-1:2004
EN 15599-1:2010
EN 15600-1:2010
Product Certification Body
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes)
System 1
EN 1125:2008
EN 1154:1996/A1:2002
EN 1154:1996/A1:2002/AC:2006
EN 1155:1996/A1:2002/AC:2006
EN 1155:1997/A1:2002
EN 1158:1997/A1:2002
EN 1158:1997/A1:2002/AC:2006
EN 12209:2003
EN 12209:2003/AC:2005
EN 14846:2008
EN 179:2008
EN 1935:2002
EN 1935:2002/AC:2003
Product Certification Body
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
System 3
EN 13241-1:2003+A1:2011
EN 14351-1:2006+A1:2010
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (fire/smoke compartmentation and on escape routes)
System 1
EN 14351-1:2006+A1:2010
Product Certification Body
99/94/EC Precast normal/lightweight/autoclaved aerated concrete products (1/1) :
• Precast normal/lightweight/autoclaved aerated concrete products (for structural use)
System 2+
EN 1168:2005+A3:2011
EN 12794:2005+A1:2007
EN 12794:2005+A1:2007/AC:2008
EN 13224:2011
EN 13225:2004
EN 13225:2004/AC:2006
EN 13225:2013
EN 13693:2004+A1:2009
EN 13747:2005+A2:2010
EN 14991:2007
EN 14992:2007+A1:2012
FPC Certification Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Additions (Type II) (for concrete, mortar and grout)
System 1+
EN 450-1:2012
Product Certification Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Admixtures (for concrete, mortar and grout)
System 2+
EN 934-2:2009+A1:2012
EN 934-3:2009+A1:2012
EN 934-4:2009
EN 934-5:2007
FPC Certification Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Concrete protection and repair products (for other uses in buildings and civil engineering works)
System 2+
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
EN 1504-5:2004
EN 1504-6:2006
EN 1504-7:2006
FPC Certification Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Fibres (for other uses in concrete, mortar and grout)
System 3
EN 14889-1:2006
Testing Laboratory
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Fibres (for structural uses in concrete, mortar and grout)
System 1
EN 14889-1:2006
Product Certification Body
99/470/EC Construction adhesives (1/2) :
• Adhesives for tiles (for internal and external uses in buildings and other civil engineering works)
System 3
EN 12004:2007+A1:2012
Testing Laboratory
99/470/EC Construction adhesives (2/2) :
• Adhesives for tiles (for uses subject to reaction to fire regulations)
System 3
EN 12004:2007+A1:2012
Testing Laboratory
99/472/EC Pipes, tanks and ancillaries not in contact with water intended for human consumption (1/5) :
• Fittings, adhesives, joints, joint sealings and gaskets (in installations for the transport/distribution/ storage of gas/fuel intended for the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building)
System 3
EN 969:2009
Testing Laboratory
99/472/EC Pipes, tanks and ancillaries not in contact with water intended for human consumption (1/5) :
• Pipes (in installations for the transport/distribution/ storage of gas/fuel intended for the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building)
System 3
EN 10255:2004+A1:2007
EN 1057:2006+A1:2010
EN 969:2009
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 12150-2:2004
EN 13024-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1863-2:2004
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Flat or curved glass panels (for uses subject to reaction to fire regulations)
System 3
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Flat or curved glass panels (for uses subject to external fire performance regulations)
System 3
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Flat or curved glass panels (for other uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) :
• Flat or curved glass panels (specially treated) (for uses relating to energy conservation and/or noise reduction)
System 3
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory

 
Horizontal notification (CPR Annex V.3)
Essential characteristics Specification Body Function
Reaction to fire EN 13823
EN ISO 1182
EN ISO 11925-2
EN ISO 1716
EN ISO 9239-1
Testing Laboratory
Resistance to fire EN 1365-3
EN 1634-1
Testing Laboratory
External fire performance TS 1187
Testing Laboratory
Set page to normal font size Increase font size by 200 percentprint this page