Navigation path


Notification

Found : 19
  Body :

IKATES, s.r.o.
Tolstého 186
415 03 TEPLICE
Country : Czech Republic

Phone : +420:417:503 093, +420:417:502 825
Fax : +420:417:502 825

Email : ikates@volny.cz
Website : www.volny.cz/ikates/ikates.htm

Notified Body number : 1394

Version(s): 1 2 3

Last update : 02/07/2009
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products
Last update : 04/06/2013                 Version(s): 1 2 3 4 5

Decision Product family, product /Intended use AoC system Technical specification Body function
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1036-2:2008
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
FPC Certification Body
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Insulating glass units (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
FPC Certification Body
Testing Laboratory
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Channel-shaped glass (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 572-9:2004
Product Certification Body
Testing Laboratory
FPC Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Insulating glass units (for uses subject to reaction to fire regulations)
System 3
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Flat or curved glass panels (for uses subject to reaction to fire regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Insulating glass units (for uses subject to external fire performance regulations)
System 3
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Flat or curved glass panels (for uses subject to external fire performance regulations)
System 3
EN 1036-2:2008
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Channel-shaped glass (for uses subject to external fire performance regulations)
System 3
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Flat or curved glass panels (for other uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
EN 1036-2:2008
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Flat or curved glass panels (for use as anti-bullet, or anti-explosion glazing)
System 1
EN 1036-2:2008
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Insulating glass units (for use as anti-bullet, or anti-explosion glazing)
System 1
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
FPC Certification Body
Testing Laboratory
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Insulating glass units (for other uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Glass-block (for other uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
EN 1051-2:2007
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Glass-block (for use as anti-bullet or anti-explosion glazing)
System 1
EN 1051-2:2007
Product Certification Body
Testing Laboratory
FPC Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Channel-shaped glass (for other uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) :
• Insulating glass units (for uses relating to energy conservation and/or noise reduction)
System 3
EN 1279-5:2005+A1:2008
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) :
• Flat or curved glass panels (specially treated) (for uses relating to energy conservation and/or noise reduction)
System 3
EN 1036-2:2008
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) :
• Glass blocks (for uses relating to energy conservation and/or noise reduction)
System 3
EN 1051-2:2007
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) :
• Channel-shaped glass (for uses relating to energy conservation and/or noise reduction)
System 3
EN 572-9:2004
Testing Laboratory