  Body :

LIGNOTESTING, A.S.
Technicka 5
821 04 BRATISLAVA 2
Country : Slovakia

Phone : +421:2:43632957
Fax : +421:2:43632958

Email : lti@lignotesting.sk
Website : www.lignotesting.sk

Notified Body number : 1478

Version(s): 1 2 3 4 5 6 7 8 9 10

Last update : 23/10/2008
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
Regulation (EU) No 305/2011 - Construction products
Last update : 18/06/2013
Decision Product family, product /Intended use AVCP system Technical specification Body function
96/577/EC Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) :
• Smoke and heat exhaust ventilation systems-kits (fire safety)
System 1
EN 12101-2:2003
Product Certification Body
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls not subject to reaction to fire requirements)
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 3
EN 13830:2003
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 1
EN 13830:2003
Product Certification Body
97/176/EC Structural timber products (1/3) :
• Solid structural timber products: Elements (bridge elements, truss elements, sleepers, floor elements, wall elements, roof elements such as beams, arches, joists, rafters, columns, poles, piles) (bridges, railtracks and buildings)
System 2+
EN 14081-1:2005+A1:2011
EN 14229:2010
EN 14250:2010
FPC Certification Body
97/176/EC Structural timber products (2/3) :
• Structural glued laminated products and other glued timber products: Elements (bridge elements, truss elements, floor elements, wall elements, roof elements such as beams, arches, joists, rafters, columns, poles, piles) (for bridges and buildings)
• Structural glued laminated products and other glued timber products: Kits (trusses, floors, walls, roofs, frames) (for bridges and buildings)
System 1
EN 14080:2005
EN 14080:2013
Product Certification Body
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external application)
System 1
EN 13986:2004
Product Certification Body
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external applications)
System 2+
EN 13986:2004
FPC Certification Body
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 1
EN 13986:2004
Product Certification Body
97/808/EC Floorings (2/2) :
• Rigid flooring products<BR>(a) Components: paving units, tiles, mosaics, parquet, decking of mesh or sheet, floor gratings, rigid laminated floorings, wood based products (for internal uses including enclosed public transport premises)
System 3
EN 14342:2005+A1:2008
EN 14342:2013
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 1
EN 14041:2004
EN 14041:2004/AC:2006
Product Certification Body
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 3
EN 14041:2004
EN 14041:2004/AC:2006
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roof windows (for uses subject to reaction to fire regulations)
System 1
EN 14351-1:2006+A1:2010
Product Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roof windows (for uses subject to reaction to fire regulations)
System 3
EN 14351-1:2006+A1:2010
Testing Laboratory
Calculation body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (3/6) :
• Roof windows (for uses subject to external fire performance regulations)
System 3
EN 14351-1:2006+A1:2010
Testing Laboratory
Calculation body
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
System 3
EN 13241-1:2003+A1:2011
EN 14351-1:2006+A1:2010
Testing Laboratory
Calculation body
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (fire/smoke compartmentation and on escape routes)
System 1
EN 14351-1:2006+A1:2010
Product Certification Body
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes)
System 1
EN 1125:2008
EN 1154:1996/A1:2002
EN 1154:1996/A1:2002/AC:2006
EN 1158:1997/A1:2002
EN 1158:1997/A1:2002/AC:2006
EN 12209:2003
EN 12209:2003/AC:2005
EN 179:2008
EN 1935:2002
EN 1935:2002/AC:2003
Product Certification Body
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Windows (with or without related hardware) (any other)
System 3
EN 14351-1:2006+A1:2010
Testing Laboratory
Calculation body
99/470/EC Construction adhesives (1/2) :
• Adhesives for tiles (for internal and external uses in buildings and other civil engineering works)
System 3
EN 12004:2007+A1:2012
Testing Laboratory

 