Navigation path


Notification

Found : 27
  Body (History):

TÜV Eesti OÜ
Vana-Narva mnt 24B
74114 Maardu
Country : Estonia

Phone : +372-6678080
Fax : +372-6678086

Email : info@tuev-nord.ee
Website : http://www.tuev-nord.ee/

Notified Body number : 1526

Version(s): 1 2 3 4 5 6 7 8 9 10 11 12 13

Last update : 08/06/2011
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products
Last update : 22/11/2012                 Version(s): 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Decision Product family, product /Intended use AoC system Technical specification Body function
95/467/EC Gypsum products (2/4) :
• Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings)
System 3
EN 12859:2011
EN 12860:2001
EN 12860:2001/AC:2002
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls not subject to reaction to fire requirements)
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 3
EN 13830:2003
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 1
EN 13830:2003
Testing Laboratory
97/176/EC Structural timber products (2/3) :
• Structural glued laminated products and other glued timber products: Elements (bridge elements, truss elements, floor elements, wall elements, roof elements such as beams, arches, joists, rafters, columns, poles, piles) (for bridges and buildings)
System 1
EN 14080:2005
EN 14374:2004
Testing Laboratory
97/176/EC Structural timber products (2/3) :
• Structural glued laminated products and other glued timber products: Kits (trusses, floors, walls, roofs, frames) (for bridges and buildings)
System 1
EN 14080:2005
Testing Laboratory
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external application)
System 1
EN 13986:2004
Testing Laboratory
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 1
EN 13986:2004
Testing Laboratory
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 3
EN 13986:2004
Testing Laboratory
98/214/EC Structural metallic products and ancillaries (1/4) :
• Structural metallic sections/profiles: hot rolled, cold formed or otherwise produced sections/profiles with various shapes (T, L, H, U, Z, I, channels, angle, hollow, tubes), flat products (plate, sheet, strip), bars, castings, forgings made of various metallic materials, unprotected or protected against corrosion by coating (to be used in metal structures or in composite metal and concrete structures)
System 2+
EN 1090-1:2009
EN 1090-1:2009+A1:2011
EN 1090-1:2009/AC:2010
FPC Certification Body
98/214/EC Structural metallic products and ancillaries (2/4) :
• Structural metallic construction members: finished metallic products such as trusses, girders, columns, stairs, ground piles, bearing piles and sheet piling, cut to size sections designed for certain applications, and rails and sleepers. They can be unprotected or protected against corrosion by coating, welded or not. (for uses in work's frames and foundations)
System 2+
EN 1090-1:2009
EN 1090-1:2009+A1:2011
EN 1090-1:2009/AC:2010
FPC Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (1/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to resistance to fire regulations (e.g. fire compartmentation))
System 3
EN 490: 2011
EN 490:2004/A1:2006
EN 492:2004
EN 492:2004/A1:2005
EN 492:2004/A2:2006
EN 494:2004+A3:2007
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (1/6) :
• Flat and profiled sheets (for uses subject to resistance to fire regulations (e.g. fire compartmentation))
System 3
EN 494:2004+A3:2007
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations)
System 3
EN 490: 2011
EN 490:2004/A1:2006
EN 492:2004
EN 492:2004/A1:2005
EN 492:2004/A2:2006
EN 494:2004+A3:2007
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Flat and profiled sheets (for uses subject to reaction to fire regulations)
System 3
EN 494:2004+A3:2007
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (3/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to external fire performance regulations)
System 3
EN 490: 2011
EN 490:2004/A1:2006
EN 492:2004
EN 492:2004/A1:2005
EN 492:2004/A2:2006
EN 494:2004+A3:2007
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (3/6) :
• Flat and profiled sheets (for uses subject to external fire performance regulations)
System 3
EN 494:2004+A3:2007
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 1
EN 13162:2008
EN 13163:2008
EN 13164:2008
EN 13165:2008
EN 13166:2008
EN 13167:2008
EN 13168:2008
EN 13169:2008
EN 13170:2008
EN 13171:2008
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14316-1:2004
EN 14317-1:2004
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13162:2008
EN 13163:2008
EN 13164:2008
EN 13165:2008
EN 13166:2008
EN 13167:2008
EN 13168:2008
EN 13169:2008
EN 13170:2008
EN 13171:2008
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14316-1:2004
EN 14317-1:2004
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes)
System 1
EN 1125:2008
EN 1154:1996/A1:2002
EN 1154:1996/A1:2002/AC:2006
EN 1155:1996/A1:2002/AC:2006
EN 1155:1997/A1:2002
EN 1158:1997/A1:2002
EN 1158:1997/A1:2002/AC:2006
EN 12209:2003
EN 12209:2003/AC:2005
EN 179:2008
EN 1935:2002
EN 1935:2002/AC:2003
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (fire/smoke compartmentation and on escape routes)
System 1
EN 14351-1:2006+A1:2010
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
• Windows (with or without related hardware) (any other)
System 3
EN 14351-1:2006+A1:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Insulating glass units (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 12150-2:2004
EN 1279-5:2005+A2:2010
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Insulating glass units (for uses subject to reaction to fire regulations)
System 3
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Flat or curved glass panels (for uses subject to reaction to fire regulations)
System 3
EN 12150-2:2004
EN 1279-5:2005+A2:2010
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Insulating glass units (for uses subject to external fire performance regulations)
System 3
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Flat or curved glass panels (for uses subject to external fire performance regulations)
System 3
EN 12150-2:2004
EN 1279-5:2005+A2:2010
EN 572-9:2004
Testing Laboratory
Set page to normal font size Increase font size by 200 percentprint this page