  Body :

UNIVERSITE DE LIEGE, LABORATOIRE D'ESSAI AU FEU
Chemin des Chevreuils 1
4000 LIEGE
Country : Belgium

Phone : +32:4:366 92 65
Fax : +32:4:366 95 34

Email : argenco@ulg.ac.be
Website : http://www.argenco.ulg.ac.be/se_labo_feu

Notified Body number : 2267

Last update : 26/11/2010
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products
Last update : 12/07/2012                 Version(s): 1 2

Decision Product family, product /Intended use AoC system Technical specification Body function
95/467/EC Gypsum products (2/4) :
• Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings)
System 3
EN 12859:2011
EN 12860:2001
EN 12860:2001/AC:2002
EN 13279-1:2008
EN 14195:2005
EN 14195:2005/AC:2006
EN 14246:2006
EN 14246:2006/AC:2007
EN 520:2004+A1:2009
ETA-09/0075
ETA-09/0076
Testing Laboratory
97/740/EC Masonry and related products (2/3) :
• Lintels (in walls and partitions)
System 3
EN 845-2:2003
Testing Laboratory
98/213/EC Internal partition kits (2/5) :
• Internal partition kits (for fire compartmentation)
System 3
ETAG 003
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (1/5) :
• Panels (as internal or external finishes, as complete elements, used for fire protection of walls or ceilings)
System 3
EN 14509:2006
EN 14509:2006/AC:2008
EN 15102:2007
EN 15102:2007+A1:2011
EN 438-7:2005
ETA-07/0086
ETA-07/0087
ETA-07/0141
ETA-08/0147
ETA-08/0343
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (1/5) :
• Suspended ceilings (kits) (as internal or external finishes used for fire protection of ceilings)
System 3
EN 13964:2004
EN 13964:2004/A1:2006
Testing Laboratory
99/92/EC Light composite wood-based beams and columns (1/1) :
• Light composite wood-based beams and columns (including T-beams, i.e. beam/slab combinations) (in buildings)
System 1
ETA-07/0032
ETA-07/0161
ETA-08/0370
ETA-09/0283
ETAG 011
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes)
System 1
EN 1125:2008
EN 1154:1996/A1:2002
EN 1154:1996/A1:2002/AC:2006
EN 1155:1996/A1:2002/AC:2006
EN 1155:1997/A1:2002
EN 1158:1997/A1:2002
EN 1158:1997/A1:2002/AC:2006
EN 12209:2003
EN 12209:2003/AC:2005
EN 179:2008
EN 1935:2002
EN 1935:2002/AC:2003
ETA-07/0045
ETA-08/0117
ETA-08/0209
ETA-09/0209
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Insulating glass units (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1279-5:2005+A2:2010
ETA-09/0206
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1036-2:2008
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005+A2:2010
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (1/6) :
• Self-supporting composite lightweight panels (for uses contributing to stiffening the structure)
System 3
ETAG 016 - 1
ETAG 016 - 2
ETAG 016 - 3
ETAG 016 - 4
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (1/6) :
• Prefabricated wood-based load-bearing stressed skin panels (for uses contributing to the load-bearing capacity of the structure)
System 1
ETAG 019
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (2/6) :
• Self-supporting composite lightweight panels (for uses subject to resistance to fire regulations (eg fire compartmentation))
System 3
ETAG 016 - 1
ETAG 016 - 2
ETAG 016 - 3
ETAG 016 - 4
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (2/6) :
• Prefabricated wood-based load-bearing stressed skin panels (for uses subject to resistance to fire regulations (eg fire compartmentation))
System 3
ETAG 019
Testing Laboratory
2003/728/EC Metal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :
• Cold storage room kits (in building works)
System 1
ETAG 021 - 1
ETAG 021 - 2
Testing Laboratory
2003/728/EC Metal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :
• Prefabricated building units (in building works)
System 1
ETAG 023
Testing Laboratory
2003/728/EC Metal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :
• Concrete frame building kits (in building works)
System 1
ETAG 024
Testing Laboratory
2003/728/EC Metal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :
• Metal frame building kits (in building works)
System 1
ETAG 025
Testing Laboratory