Navigation path


Notification

Found : 18
  Body :

MATERIALPRÜFUNGS- UND VERSUCHSANSTALT NEUWIED GMBH
Sandkauler Weg 1
56564 NEUWIED
Country : Germany

Phone : +49:263:139 93 0
Fax : +49:263:139 93 40

Email : info@mpva.de
Website : www.mpva.de

Notified Body number : 1033

Version(s): 1 2 3

Last update : 05/03/2007
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products
Last update : 30/01/2012                 Version(s): 1 2 3 4 5 6

Decision Product family, product /Intended use AoC system Technical specification Body function
95/467/EC Chimneys, flues and specific products (1/1) :
• Prefabricated chimneys (storey height elements), flue liners (elements or blocks), multi-shell chimney (elements or blocks), single walled chimneys and attached chimneys (chimneys)
System 2+
EN 12446:2011
EN 1858:2008+A1:2011
FPC Certification Body
Inspection Body
97/740/EC Masonry and related products (1/3) :
• Factory-made, designed masonry mortars (in walls, columns and partitions)
System 2+
EN 998-2:2010
FPC Certification Body
Inspection Body
97/740/EC Masonry and related products (1/3) :
• Masonry units category I (in walls, columns and partitions)
System 2+
EN 771-1:2011
EN 771-2:2011
EN 771-3:2011
EN 771-4:2011
Inspection Body
FPC Certification Body
98/437/EC Internal and external wall and ceiling finishes (2/5) :
• Tiles (of brittle materials) (as internal or external finishes in walls or ceilings subject to requirements against accidental injuries from cutting objects)
System 3
EN 14411:2006
EN 14411:2012
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (2/5) :
• Tiles (in internal or external suspended ceilings subject to safety in use requirements)
System 3
EN 12057:2004
EN 14411:2006
EN 14411:2012
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Tiles (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 3
EN 12057:2004
EN 14411:2006
EN 14411:2012
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (4/5) :
• Tiles (as internal or external finishes in walls or ceilings, as relevant, subject to regulations on dangerous substances)
System 3
EN 12057:2004
EN 14411:2006
EN 14411:2012
Testing Laboratory
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Aggregates and fillers for concrete, mortar and grout (in buildings, roads and other civil engineering work)
System 2+
EN 12620:2002+A1:2008
EN 13055-1:2002
EN 13055-1:2002/AC:2004
EN 13055-2:2004
EN 13139:2002
EN 13139:2002/AC:2004
FPC Certification Body
Inspection Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Aggregates for bituminous mixtures and surface treatments (for roads and other civil engineering works)
System 2+
EN 13043:2002
EN 13043:2002/AC:2004
EN 13055-2:2004
FPC Certification Body
Inspection Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Aggregates for unbound and hydraulically bound mixtures (for roads and other civil engineering works)
System 2+
EN 13055-2:2004
EN 13242:2002+A1:2007
FPC Certification Body
Inspection Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Armourstones (for hydraulic structures and other civil engineering works)
• Railway ballast (for railway works)
• Fillers for bituminous mixtures and surface treatments (for roads and other civil engineering works)
System 2+
EN 13055-2:2004
FPC Certification Body
Inspection Body
99/91/EC Thermal insulating products (1/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (any)
System 3
EN 13168:2008
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14316-1:2004
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 1
EN 13168:2008
Product Certification Body
Inspection Body
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13168:2008
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14316-1:2004
Testing Laboratory
99/94/EC Precast normal/lightweight/autoclaved aerated concrete products (1/1) :
• Precast normal/lightweight/autoclaved aerated concrete products (for structural use)
System 2+
EN 1168:2005+A2:2009
EN 1168:2005+A3:2011
EN 12843:2004
EN 13224:2004+A1:2007
EN 13224:2011
EN 13225:2004
EN 13225:2004/AC:2006
EN 13693:2004+A1:2009
EN 14992:2007
EN 1520:2011
FPC Certification Body
Inspection Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Concrete protection and repair products (for other uses in buildings and civil engineering works)
System 2+
EN 1504-3:2005
Inspection Body
FPC Certification Body
99/470/EC Construction adhesives (1/2) :
• Adhesives for tiles (for internal and external uses in buildings and other civil engineering works)
System 3
EN 12004:2007
Testing Laboratory
99/470/EC Construction adhesives (2/2) :
• Adhesives for tiles (for uses subject to reaction to fire regulations)
System 3
EN 12004:2007
Testing Laboratory
Set page to normal font size Increase font size by 200 percentprint this page