  Body (History):

Cambridge Fire Research Limited
Brewery Road, Pampisford
Cambridge CB22 3HG
Country : United Kingdom

Phone : 00441223834752
Fax : -

Email : testing@cambridge-fire.co.uk
Website : www.cambridge-fire.co.uk

Notified Body number : 2337

Version(s): 1 2

Last update : 10/10/2011
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products
Last update : 10/10/2011
Decision Product family, product /Intended use AoC system Technical specification Body function
95/467/EC Gypsum products (1/4) :
• Plasterboards and ceiling elements with thin laminations, fibrous gypsum boards, fibrous gypsum plaster casts, and composite panels (laminates), in which the incorporated material is placed on a face susceptible to be explosed to fire, including relevant ancillary products (in walls, partitions or ceilings (or lining thereof) subject to reaction to fire requirements)
System 3
EN 13950:2005
EN 14190:2005
EN 14496:2005
EN 520:2004+A1:2009
Testing Laboratory
95/467/EC Gypsum products (2/4) :
• Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings)
System 3
EN 12859:2011
EN 13279-1:2008
EN 520:2004+A1:2009
Testing Laboratory
95/467/EC Gypsum products (3/4) :
• Plasterboards, including relevant ancillary products (for stiffening timber-framed windload bearing walls or timber roof struss structures)
System 3
EN 14190:2005
EN 520:2004+A1:2009
Testing Laboratory
97/740/EC Masonry and related products (2/3) :
• Lintels (in walls and partitions)
System 3
EN 845-2:2003
Testing Laboratory
98/213/EC Internal partition kits (1/5) :
• Internal partition kits (for uses subject to reaction to fire requirements)
System 3
ETAG 003
Testing Laboratory
98/213/EC Internal partition kits (2/5) :
• Internal partition kits (for fire compartmentation)
System 3
ETAG 003
Testing Laboratory
98/279/EC Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1) :
• Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)
System 1
ETAG 009
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (1/5) :
• Panels (as internal or external finishes, as complete elements, used for fire protection of walls or ceilings)
System 3
EN 438-7:2005
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
System 3
EN 14351-1:2006+A1:2010
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes)
System 1
EN 1125:2008
EN 1154:1996/A1:2002
EN 1154:1996/A1:2002/AC:2006
EN 1155:1996/A1:2002/AC:2006
EN 1155:1997/A1:2002
EN 1158:1997/A1:2002
EN 1158:1997/A1:2002/AC:2006
EN 12209:2003
EN 12209:2003/AC:2005
EN 179:2008
EN 1935:2002
EN 1935:2002/AC:2003
Testing Laboratory
99/454/EC Fire stopping, fire sealing and fire protection products (1/2) :
• Fire protective products (including coatings) (for fire compartmentation and/or fire protection or fire performance)
System 1
ETAG 018 - 1
ETAG 018 - 3
ETAG 018 - 4
ETAG 018 - 4 Amendment
Testing Laboratory
99/454/EC Fire stopping, fire sealing and fire protection products (1/2) :
• Fire stopping, fire sealing products (for fire compartmentation and/or fire protection or fire performance)
System 1
ETAG 018 - 1
ETAG 018 - 3
ETAG 018 - 4
ETAG 018 - 4 Amendment
ETAG 026 - 1
ETAG 026 - 2
ETAG 026 - 3
Testing Laboratory
99/454/EC Fire stopping, fire sealing and fire protective products (2/2) :
• Fire protective products (including coatings) (for uses subject to reaction to fire regulations)
System 1
ETAG 018 - 1
ETAG 018 - 3
ETAG 018 - 4
ETAG 018 - 4 Amendment
Testing Laboratory
99/454/EC Fire stopping, fire sealing and fire protective products (2/2) :
• Fire stopping and fire sealing products (for uses subject to reaction to fire regulations)
System 1
ETAG 018 - 1
ETAG 018 - 3
ETAG 018 - 4
ETAG 018 - 4 Amendment
ETAG 026 - 1
ETAG 026 - 2
ETAG 026 - 3
Testing Laboratory
99/455/EC Timber frame and log prefabricated building kits (1/1) :
• Timber frame and log prefabricated building kits (as defined in Annex I) (in building works)
System 1
ETAG 007
ETAG 012
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Insulating glass units (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1279-5:2005+A2:2010
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005+A2:2010
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (2/6) :
• Self-supporting composite lightweight panels (for uses subject to resistance to fire regulations (eg fire compartmentation))
System 3
ETAG 016 - 1
ETAG 016 - 4
Testing Laboratory
2003/728/EC Metal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :
• Cold storage room kits (in building works)
System 1
ETAG 021 - 1
ETAG 021 - 2
Testing Laboratory
2003/728/EC Metal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :
• Prefabricated building units (in building works)
System 1
ETAG 023
Testing Laboratory
2003/728/EC Metal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :
• Concrete frame building kits (in building works)
System 1
ETAG 024
Testing Laboratory
2003/728/EC Metal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits :
• Metal frame building kits (in building works)
System 1
ETAG 025
Testing Laboratory