Navigation path


Notification

Found : 46
  Body :

Warrington Certification Limited
Holmesfield Road
Warrington WA1 2DS
Country : United Kingdom

Phone : +44 (0) 1925 646609 or +44 (0) 1925 646666
Fax : +44 (0) 1925 646667

Email : paul.duggan@exova.com or chris.moores@exova.com
Website : www.exova.com

Notified Body number : 1121

Version(s): 1 2 3 4 5 6 7 8

Last update : 24/05/2013
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products
Last update : 19/11/2010                 Version(s): 1 2 3 4 5 6 7 8

Decision Product family, product /Intended use AoC system Technical specification Body function
96/577/EC Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) :
• Smoke and heat exhaust ventilation systems-kits (fire safety)
System 1
EN 12101-2:2003
EN 12101-3:2002
EN 12101-3:2002/AC:2005
FPC Certification Body
Product Certification Body
96/577/EC Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) :
• Smoke curtains (fire safety)
System 1
EN 12101-1:2005
EN 12101-1:2005/A1:2006
Product Certification Body
FPC Certification Body
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 1
EN 13830:2003
FPC Certification Body
Product Certification Body
96/582/EC Structural sealant glazing kits of types (curtain walling) :
• Structural sealant glazing kits, Types II and IV (for external walls and roofs)
System 1
ETAG 002 - 1
ETAG 002 - 2
ETAG 002 - 3
FPC Certification Body
Product Certification Body
97/176/EC Structural timber products (1/3) :
• Solid structural timber products: Elements (bridge elements, truss elements, sleepers, floor elements, wall elements, roof elements such as beams, arches, joists, rafters, columns, poles, piles) (bridges, railtracks and buildings)
• Solid structural timber products; Kits (trusses, floors, walls, roofs, frames) (bridges, railtracks and buildings)
System 1
EN 14374:2004
FPC Certification Body
Product Certification Body
97/176/EC Structural timber products (1/3) :
• Solid structural timber products; Kits (trusses, floors, walls, roofs, frames) (bridges, railtracks and buildings)
• Solid structural timber products: Elements (bridge elements, truss elements, sleepers, floor elements, wall elements, roof elements such as beams, arches, joists, rafters, columns, poles, piles) (bridges, railtracks and buildings)
System 2+
EN 14250:2010
FPC Certification Body
97/176/EC Structural timber products (2/3) :
• Structural glued laminated products and other glued timber products: Elements (bridge elements, truss elements, floor elements, wall elements, roof elements such as beams, arches, joists, rafters, columns, poles, piles) (for bridges and buildings)
System 1
EN 14080:2005
EN 14374:2004
FPC Certification Body
Product Certification Body
97/176/EC Structural timber products (2/3) :
• Structural glued laminated products and other glued timber products: Kits (trusses, floors, walls, roofs, frames) (for bridges and buildings)
System 1
EN 14080:2005
FPC Certification Body
Product Certification Body
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external application)
System 1
EN 13986:2004
FPC Certification Body
Product Certification Body
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external applications)
System 2+
EN 13986:2004
FPC Certification Body
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 1
EN 13986:2004
FPC Certification Body
Product Certification Body
97/556/EC External thermal insulation composite systems/kits with rendering (ETICS)(1/1) :
• External thermal insulation composite systems/kits with rendering (ETICS) (in external wall not subject to fire regulations)
• External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)
System 2+
ETAG 004 Version 08/2011
FPC Certification Body
97/556/EC External thermal insulation composite systems/kits with rendering (ETICS)(1/1) :
• External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)
System 1
ETAG 004 Version 08/2011
Product Certification Body
FPC Certification Body
97/740/EC Masonry and related products (3/3) :
• Masonry units incorporating thermal insulating materials placed on a face susceptible to be exposed to fire (in walls and partitions subject to reaction to fire regulations)
System 1
EN 15824:2009
FPC Certification Body
Product Certification Body
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 1
EN 14041:2004
EN 14041:2004/AC:2006
EN 14904:2006
FPC Certification Body
Product Certification Body
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 1
EN 13454-1:2004
EN 13813:2002
Product Certification Body
FPC Certification Body
98/213/EC Internal partition kits (1/5) :
• Internal partition kits (for uses subject to reaction to fire requirements)
System 1
ETAG 003
FPC Certification Body
Product Certification Body
98/279/EC Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1) :
• Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)
System 1
ETAG 009
FPC Certification Body
Product Certification Body
98/279/EC Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1) :
• Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)
• Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: panels made of an insulating material (or a combination of an insulating material and other materials), consisting of shuttering leaves linked by spacers (for the construction of external and internal walls not subject to fire regulations, in buildings)
System 2+
ETAG 009
FPC Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Rooflights (for uses subject to reaction to fire regulations)
System 1
EN 14963:2006
EN 1873:2005
FPC Certification Body
Product Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Factory-bonded composite or sandwich panels (for uses subject to reaction to fire regulations)
System 1
EN 14509:2006
EN 14509:2006/AC:2008
FPC Certification Body
Product Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roof windows (for uses subject to reaction to fire regulations)
System 1
EN 14351-1:2006+A1:2010
FPC Certification Body
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations)
System 1
EN 13964:2004
EN 13964:2004/A1:2006
FPC Certification Body
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Coverings in roll form (as internal finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 14716:2004
EN 15102:2007+A1:2011
FPC Certification Body
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Panels (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 15102:2007+A1:2011
EN 438-7:2005
FPC Certification Body
Product Certification Body
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Sidings (as internal or external finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 13245-2:2008
EN 13245-2:2008/AC:2009
FPC Certification Body
Product Certification Body
98/599/EC Liquid applied roof waterproofing kits (3/3) :
• Liquid applied roof waterproofing kits (for uses subject to reaction to fire regulations)
System 1
ETAG 005
FPC Certification Body
Product Certification Body
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (3/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
System 1
ETAG 010
FPC Certification Body
Product Certification Body
99/89/EC Prefabricated stair kits (2/2) :
• Prefabricated stair kits (for uses subject to reaction to fire regulations)
System 1
ETAG 008
FPC Certification Body
Product Certification Body
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 1
EN 13967:2004
EN 13967:2004/A1:2006
EN 13969:2004
EN 13969:2004/A1:2006
FPC Certification Body
Product Certification Body
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 1
EN 13859-1:2010
FPC Certification Body
Product Certification Body
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 1
EN 13707:2004+A2:2009
EN 13956:2005
EN 13956:2005/AC:2006
EN 13956:2012
FPC Certification Body
Product Certification Body
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 1
EN 13859-1:2010
EN 13859-2:2010
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2004
EN 13984:2004/A1:2006
EN 13984:2013
FPC Certification Body
Product Certification Body
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 1
EN 13162:2008
EN 13163:2008
EN 13164:2008
EN 13165:2008
EN 13166:2008
EN 13167:2008
EN 13168:2008
EN 13169:2008
EN 13170:2008
EN 13171:2008
EN 14064-1:2010
EN 14303:2009
EN 14303:2009+A1:2013
EN 14304:2009
EN 14304:2009+A1:2013
EN 14305:2009
EN 14305:2009+A1:2013
EN 14306:2009
EN 14306:2009+A1:2013
EN 14307:2009
EN 14307:2009+A1:2013
EN 14308:2009
EN 14308:2009+A1:2013
EN 14309:2009
EN 14309:2009+A1:2013
EN 14313:2009
EN 14313:2009+A1:2013
EN 14314:2009
EN 14314:2009+A1:2013
EN 14316-1:2004
EN 14317-1:2004
EN 14933:2007
EN 14934:2007
FPC Certification Body
Product Certification Body
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes)
System 1
EN 1125:2008
EN 1154:1996/A1:2002
EN 1154:1996/A1:2002/AC:2006
EN 1155:1996/A1:2002/AC:2006
EN 1155:1997/A1:2002
EN 1158:1997/A1:2002
EN 1158:1997/A1:2002/AC:2006
EN 12209:2003
EN 12209:2003/AC:2005
EN 179:2008
EN 1935:2002
EN 1935:2002/AC:2003
FPC Certification Body
Product Certification Body
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (fire/smoke compartmentation and on escape routes)
System 1
EN 14351-1:2006+A1:2010
FPC Certification Body
Product Certification Body
99/454/EC Fire stopping, fire sealing and fire protection products (1/2) :
• Fire stopping, fire sealing products (for fire compartmentation and/or fire protection or fire performance)
System 1
ETAG 018 - 1
ETAG 018 - 2
ETAG 018 - 3
ETAG 018 - 4
ETAG 018 - 4 Amendment
ETAG 026 - 1
ETAG 026 - 2 Version 08/2011
ETAG 026 - 3 Version 08/2011
FPC Certification Body
Product Certification Body
99/454/EC Fire stopping, fire sealing and fire protection products (1/2) :
• Fire protective products (including coatings) (for fire compartmentation and/or fire protection or fire performance)
System 1
ETAG 018 - 1
ETAG 018 - 2
ETAG 018 - 3
ETAG 018 - 4
ETAG 018 - 4 Amendment
FPC Certification Body
Product Certification Body
99/454/EC Fire stopping, fire sealing and fire protective products (2/2) :
• Fire protective products (including coatings) (for uses subject to reaction to fire regulations)
System 1
ETAG 018 - 1
ETAG 018 - 2
ETAG 018 - 3
ETAG 018 - 4
ETAG 018 - 4 Amendment
FPC Certification Body
Product Certification Body
99/454/EC Fire stopping, fire sealing and fire protective products (2/2) :
• Fire stopping and fire sealing products (for uses subject to reaction to fire regulations)
System 1
ETAG 018 - 1
ETAG 018 - 2
ETAG 018 - 3
ETAG 018 - 4
ETAG 018 - 4 Amendment
ETAG 026 - 1
ETAG 026 - 2 Version 08/2011
ETAG 026 - 3 Version 08/2011
FPC Certification Body
Product Certification Body
99/455/EC Timber frame and log prefabricated building kits (1/1) :
• Timber frame and log prefabricated building kits (as defined in Annex I) (in building works)
System 1
ETAG 007
ETAG 012
FPC Certification Body
Product Certification Body
99/469/EC Products related to concrete, mortar and grout (2/2) :
• Concrete protection and repair products (for uses subject to reaction to fire regulations)
System 1
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
FPC Certification Body
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Insulating glass units (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 12150-2:2004
EN 1279-5:2005+A2:2010
EN 572-9:2004
FPC Certification Body
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
FPC Certification Body
Product Certification Body
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (3/6) :
• Prefabricated wood-based load-bearing stressed skin panels (for uses subject to reaction to fire regulations)
System 1
ETAG 019
FPC Certification Body
Product Certification Body
2000/447/EC Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (3/6) :
• Self-supporting composite lightweight panels (for uses subject to reaction to fire regulations)
System 1
ETAG 016 - 1
ETAG 016 - 2
ETAG 016 - 3
ETAG 016 - 4
FPC Certification Body
Product Certification Body
Set page to normal font size Increase font size by 200 percentprint this page