Navigation path


Notification

Found : 51
  Body (History):

CIDEMCO/CENTRO DE INVESTIGACIÓN TECNOLÓGICA
Pol. Lasao/Área Anardi n°5 - Apart 134
20730 AZPEITIA
Country : Spain

Phone : +34:943:816800
Fax : +34:943:816074

Email : asier.maiztegi@cidemco.es
Website : -

Notified Body number : 1239

Version(s): 1 2 3 4 5 6 7 8 9 10

Last update : 28/05/2009
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products (History)
Last update : 28/05/2009                 Version(s): 1 2 3 4 5 6 7

Decision Product family, product /Intended use AoC system Technical specification Body function
95/467/EC Gypsum products (2/4) :
• Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings)
System 3
EN 12859:2001
EN 12859:2001/A1:2004
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 1
EN 13830:2003
Product Certification Body
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
• Curtain wall kits (as external walls not subject to reaction to fire requirements)
System 3
EN 13830:2003
Testing Laboratory
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external application)
System 1
EN 13986:2004
Product Certification Body
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external applications)
System 2+
EN 13986:2004
FPC Certification Body
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 1
EN 13986:2004
Product Certification Body
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 3
EN 13986:2004
Testing Laboratory
97/740/EC Masonry and related products (1/3) :
• Masonry units category I (in walls, columns and partitions)
System 2+
EN 771-1:2003
EN 771-1:2003/A1:2005
EN 771-2:2003
EN 771-2:2003/A1:2005
EN 771-3:2003
EN 771-3:2003/A1:2005
EN 771-4:2003
EN 771-4:2003/A1:2005
EN 771-5:2003
EN 771-5:2003/A1:2005
EN 771-6:2005
FPC Certification Body
97/740/EC Masonry and related products (1/3) :
• Factory-made, designed masonry mortars (in walls, columns and partitions)
System 2+
EN 998-2:2003
FPC Certification Body
97/740/EC Masonry and related products (2/3) :
• Lintels (in walls and partitions)
System 3
EN 845-2:2003
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 3
EN 14041:2004
EN 14041:2004/AC:2006
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 1
EN 14041:2004
EN 14041:2004/AC:2006
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roof windows (for uses subject to reaction to fire regulations)
System 3
EN 14351-1:2006
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roof windows (for uses subject to reaction to fire regulations)
System 1
EN 14351-1:2006
Product Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations)
System 3
EN 544:2005
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Flat and profiled sheets (for uses subject to reaction to fire regulations)
System 1
EN 534:2006
Product Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Flat and profiled sheets (for uses subject to reaction to fire regulations)
System 3
EN 534:2006
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (3/6) :
• Roof windows (for uses subject to external fire performance regulations)
System 3
EN 14351-1:2006
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (1/5) :
• Panels (as internal or external finishes, as complete elements, used for fire protection of walls or ceilings)
System 3
EN 438-7:2005
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (2/5) :
• Panels (as internal or external stiffening elements in walls or ceilings)
System 3
EN 438-7:2005
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (4/5) :
• Panels (as internal or external finishes in walls or ceilings, as relevant, subject to regulations on dangerous substances)
System 3
EN 438-7:2005
Testing Laboratory
99/90/EC Membranes (1/3) :
• Roof underlays (in buildings)
System 3
EN 13859-1:2005
Testing Laboratory
99/90/EC Membranes (1/3) :
• Water vapour control layers (in buildings)
System 3
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2004
EN 13984:2004/A1:2006
Testing Laboratory
99/90/EC Membranes (1/3) :
• Damp proof courses (in buildings)
System 3
EN 14909:2006
EN 14967:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 1
EN 13967:2004
EN 13967:2004/A1:2006
EN 13969:2004
EN 13969:2004/A1:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 3
EN 13967:2004
EN 13967:2004/A1:2006
EN 13969:2004
EN 13969:2004/A1:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 1
EN 13859-1:2005
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 3
EN 13859-1:2005
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 1
EN 13707:2004
EN 13707:2004/A1:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 3
EN 13707:2004
EN 13707:2004/A1:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 1
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2004
EN 13984:2004/A1:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 3
EN 13970:2004
EN 13970:2004/A1:2006
EN 13984:2004
EN 13984:2004/A1:2006
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proof courses (for uses subject to reaction to fire regulations)
System 1
EN 14909:2006
EN 14967:2006
Product Certification Body
99/90/EC Membranes (2/3) :
• Damp proof courses (for uses subject to reaction to fire regulations)
System 3
EN 14909:2006
EN 14967:2006
Testing Laboratory
99/90/EC Membranes (3/3) :
• Roof sheets (for uses subject to external fire performance regulations)
System 3
EN 13707:2004
EN 13707:2004/A1:2006
Testing Laboratory
99/90/EC Membranes (3/3) :
• Roof underlays (for uses subject to external fire performance regulations)
System 3
EN 13859-1:2005
Testing Laboratory
99/91/EC Thermal insulating products (1/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (any)
System 3
EN 13162:2001
EN 13162:2001/AC:2005
EN 13163:2001
EN 13163:2001/AC:2005
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13164:2001/AC:2005
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13165:2001/A2:2004
EN 13165:2001/AC:2005
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13166:2001/AC:2005
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13167:2001/AC:2005
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13168:2001/AC:2005
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13169:2001/AC:2005
EN 13170:2001
EN 13170:2001/AC:2005
EN 13171:2001
EN 13171:2001/ A1:2004
EN 13171:2001/AC:2005
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13162:2001
EN 13162:2001/AC:2005
EN 13163:2001
EN 13163:2001/AC:2005
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13164:2001/AC:2005
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13165:2001/A2:2004
EN 13165:2001/AC:2005
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13166:2001/AC:2005
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13167:2001/AC:2005
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13168:2001/AC:2005
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13169:2001/AC:2005
EN 13170:2001
EN 13170:2001/AC:2005
EN 13171:2001
EN 13171:2001/ A1:2004
EN 13171:2001/AC:2005
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 1
EN 13162:2001
EN 13162:2001/AC:2005
EN 13163:2001
EN 13163:2001/AC:2005
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13164:2001/AC:2005
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13165:2001/A2:2004
EN 13165:2001/AC:2005
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13166:2001/AC:2005
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13167:2001/AC:2005
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13168:2001/AC:2005
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13169:2001/AC:2005
EN 13170:2001
EN 13170:2001/AC:2005
EN 13171:2001
EN 13171:2001/ A1:2004
EN 13171:2001/AC:2005
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
System 3
EN 13241-1:2003
EN 14351-1:2006
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes)
System 1
EN 1125:1997/A1:2001
EN 1125:1997/A1:2001/AC:2002
EN 1154:1996/A1:2002
EN 1155:1997/A1:2002
EN 1158:1997/A1:2002
EN 1158:1997/A1:2002/AC:2006
EN 12209:2003
EN 12209:2003/AC:2005
EN 179:1997/A1:2001
EN 179:1997/A1:2001/AC:2002
EN 1935:2002
EN 1935:2002/AC:2003
Product Certification Body
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Windows (with or without related hardware) (any other)
System 3
EN 14351-1:2006
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (fire/smoke compartmentation and on escape routes)
System 1
EN 14351-1:2006
Product Certification Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Admixtures (for concrete, mortar and grout)
System 2+
EN 934-2:2001
EN 934-2:2001/A1:2004
EN 934-2:2001/A2:2005
FPC Certification Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Concrete protection and repair products (for other uses in buildings and civil engineering works)
System 2+
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
EN 1504-5:2004
FPC Certification Body
99/469/EC Products related to concrete, mortar and grout (2/2) :
• Concrete protection and repair products (for uses subject to reaction to fire regulations)
System 3
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
Testing Laboratory
99/469/EC Products related to concrete, mortar and grout (2/2) :
• Concrete protection and repair products (for uses subject to reaction to fire regulations)
System 1
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Insulating glass units (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1279-5:2005
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Insulating glass units (for uses subject to reaction to fire regulations)
System 3
EN 1279-5:2005
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Flat or curved glass panels (for uses subject to reaction to fire regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 14449:2005/AC:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
Set page to normal font size Increase font size by 200 percentprint this page