Navigation path


Notification

Found : 34
  Body :

VENETA ENGINEERING SRL
Via Lovanio, 8/10
37135 - VERONA
Country : Italy

Phone : +39 045 8200948
Fax : +39. 045 8201982

Email : segreteria@venetaengineering.it
Website : www.venetaengineeering.it

Notified Body number : 0505

Version(s): 1 2 3 4 5 6 7

Last update : 06/01/2010
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products
Last update : 09/12/2009                 Version(s): 1 2 3

Decision Product family, product /Intended use AoC system Technical specification Body function
96/579/EC Circulation fixtures (1/2) :
• Road marking products: retroreflecting road studs (for circulation area)
System 1
EN 1463-1:2009
Inspection Body
Testing Laboratory
Product Certification Body
96/579/EC Circulation fixtures (1/2) :
• Road lighting columns (for circulation areas)
System 1
EN 40-4:2005
EN 40-4:2005/AC:2006
EN 40-5:2002
EN 40-6:2002
EN 40-7:2002
Inspection Body
Testing Laboratory
Product Certification Body
96/579/EC Circulation fixtures (1/2) :
• Road traffic signs and traffic control devices installed permanently for vehicular and pedestrian uses: traffic lights and fixed danger lamps (for circulation areas)
System 1
EN 12368:2006
Inspection Body
Testing Laboratory
Product Certification Body
96/579/EC Circulation fixtures (1/2) :
• Road marking products: Drop-on materials (glass beads, anti-skid aggregates and combinations of the two) (for circulation areas)
System 1
EN 1423:2012
EN 1423:2012/AC:2013
EN 1463-1:2009
Inspection Body
Testing Laboratory
Product Certification Body
96/579/EC Circulation fixtures (2/2) :
• Anti-glare screens (for circulation areas)
• Road traffic noise reducing devices and barriers (for circulation areas)
System 3
EN 12676-1:2000/A1:2003
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 1
EN 14041:2004
EN 14041:2004/AC:2006
EN 14904:2006
Inspection Body
Testing Laboratory
Product Certification Body
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 1
EN 13454-1:2004
EN 13813:2002
Inspection Body
Testing Laboratory
Product Certification Body
97/808/EC Floorings (2/2) :
• Rigid flooring products<BR>(a) Components: paving units, tiles, mosaics, parquet, decking of mesh or sheet, floor gratings, rigid laminated floorings, wood based products (for internal uses including enclosed public transport premises)
System 3
EN 12057:2004
EN 12058:2004
EN 14342:2005+A1:2008
EN 14411:2006
EN 14411:2012
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 3
EN 14041:2004
EN 14041:2004/AC:2006
EN 14904:2006
Testing Laboratory
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 3
EN 13454-1:2004
EN 13813:2002
EN 14016-1:2004
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (1/6) :
• Roofing tiles, slates, stones and shingles (for uses subject to resistance to fire regulations (e.g. fire compartmentation))
System 3
EN 1304:2005
EN 490: 2011
EN 490:2004/A1:2006
EN 492:2004
EN 492:2004/A1:2005
EN 492:2004/A2:2006
EN 494:2004+A3:2007
EN 544:2011
Testing Laboratory
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (1/6) :
• Flat and profiled sheets (for uses subject to resistance to fire regulations (e.g. fire compartmentation))
System 3
EN 494:2004+A3:2007
Testing Laboratory
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Armourstones (for hydraulic structures and other civil engineering works)
System 2+
EN 12620:2002+A1:2008
EN 13043:2002
EN 13043:2002/AC:2004
EN 13055-1:2002
EN 13055-1:2002/AC:2004
EN 13055-2:2004
EN 13139:2002
EN 13139:2002/AC:2004
EN 13242:2002+A1:2007
EN 13383-1:2002
EN 13383-1:2002/AC:2004
EN 13450:2002
EN 13450:2002/AC:2004
FPC Certification Body
Inspection Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Railway ballast (for railway works)
• Aggregates for unbound and hydraulically bound mixtures (for roads and other civil engineering works)
System 2+
EN 12620:2002+A1:2008
EN 13043:2002
EN 13043:2002/AC:2004
EN 13055-1:2002
EN 13055-1:2002/AC:2004
EN 13055-2:2004
EN 13139:2002
EN 13139:2002/AC:2004
EN 13242:2002+A1:2007
EN 13383-1:2002
EN 13383-1:2002/AC:2004
EN 13450:2002
EN 13450:2002/AC:2004
FPC Certification Body
Inspection Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Aggregates and fillers for concrete, mortar and grout (in buildings, roads and other civil engineering work)
System 2+
EN 12620:2002+A1:2008
EN 13043:2002
EN 13043:2002/AC:2004
EN 13055-1:2002
EN 13055-1:2002/AC:2004
EN 13055-2:2004
EN 13139:2002
EN 13139:2002/AC:2004
EN 13242:2002+A1:2007
EN 13383-1:2002
EN 13383-1:2002/AC:2004
EN 13450:2002
EN 13450:2002/AC:2004
FPC Certification Body
Inspection Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Aggregates for bituminous mixtures and surface treatments (for roads and other civil engineering works)
System 2+
EN 12620:2002+A1:2008
EN 13043:2002
EN 13043:2002/AC:2004
EN 13055-1:2002
EN 13055-1:2002/AC:2004
EN 13055-2:2004
EN 13139:2002
EN 13139:2002/AC:2004
EN 13242:2002+A1:2007
EN 13383-1:2002
EN 13383-1:2002/AC:2004
EN 13450:2002
EN 13450:2002/AC:2004
FPC Certification Body
Inspection Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Fillers for bituminous mixtures and surface treatments (for roads and other civil engineering works)
System 2+
EN 12620:2002+A1:2008
EN 13043:2002
EN 13043:2002/AC:2004
EN 13055-1:2002
EN 13055-1:2002/AC:2004
EN 13055-2:2004
EN 13139:2002
EN 13139:2002/AC:2004
EN 13242:2002+A1:2007
EN 13383-1:2002
EN 13383-1:2002/AC:2004
EN 13450:2002
EN 13450:2002/AC:2004
FPC Certification Body
Inspection Body
98/601/EC Road construction products (1/2) :
• Bituminous mixtures (for road construction and surface treatment of roads)
System 2+
EN 13108-1:2006
EN 13108-1:2006/AC:2008
EN 13108-7:2006
EN 13108-7:2006/AC:2008
FPC Certification Body
Inspection Body
98/601/EC Road construction products (2/2) :
• Bituminous mixtures (for uses subject to reaction to fire regulations)
System 1
EN 13108-1:2006
EN 13108-1:2006/AC:2008
EN 13108-7:2006
EN 13108-7:2006/AC:2008
Inspection Body
Testing Laboratory
Product Certification Body
98/601/EC Road construction products (2/2) :
• Bituminous mixtures (for uses subject to reaction to fire regulations)
System 3
EN 13108-1:2006
EN 13108-1:2006/AC:2008
EN 13108-7:2006
EN 13108-7:2006/AC:2008
Testing Laboratory
99/91/EC Thermal insulating products (1/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (any)
System 3
EN 13162:2008
EN 13163:2008
EN 13164:2008
EN 13165:2008
EN 13166:2008
EN 13167:2008
EN 13168:2008
EN 13169:2008
EN 13170:2008
EN 13171:2008
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14316-1:2004
EN 14317-1:2004
EN 14933:2007
EN 14934:2007
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 1
EN 13162:2008
EN 13163:2008
EN 13164:2008
EN 13165:2008
EN 13166:2008
EN 13167:2008
EN 13168:2008
EN 13169:2008
EN 13170:2008
EN 13171:2008
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14316-1:2004
EN 14317-1:2004
EN 14933:2007
EN 14934:2007
Inspection Body
Testing Laboratory
Product Certification Body
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13162:2008
EN 13163:2008
EN 13164:2008
EN 13165:2008
EN 13166:2008
EN 13167:2008
EN 13168:2008
EN 13169:2008
EN 13170:2008
EN 13171:2008
EN 14063-1:2004
EN 14063-1:2004/AC:2006
EN 14316-1:2004
EN 14317-1:2004
EN 14933:2007
EN 14934:2007
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
System 3
EN 13241-1:2003+A1:2011
EN 14351-1:2006+A1:2010
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Windows (with or without related hardware) (any other)
System 3
EN 14351-1:2006+A1:2010
Testing Laboratory
99/94/EC Precast normal/lightweight/autoclaved aerated concrete products (1/1) :
• Precast normal/lightweight/autoclaved aerated concrete products (for structural use)
System 2+
EN 1168:2005+A2:2009
EN 1168:2005+A3:2011
EN 12794:2005+A1:2007
EN 12794:2005+A1:2007/AC:2008
EN 12843:2004
EN 13224:2004+A1:2007
EN 13224:2011
EN 13225:2004
EN 13225:2004/AC:2006
EN 13693:2004+A1:2009
EN 13747:2005+A2:2010
EN 13978-1:2005
EN 14843:2007
EN 14991:2007
EN 1520:2011
FPC Certification Body
Inspection Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Fibres (for structural uses in concrete, mortar and grout)
System 1
EN 14889-1:2006
EN 14889-2:2006
Inspection Body
Testing Laboratory
Product Certification Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Concrete protection and repair products (for other uses in buildings and civil engineering works)
System 2+
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
EN 1504-5:2004
EN 1504-6:2006
EN 1504-7:2006
FPC Certification Body
Inspection Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Additions (type I) (for concrete, mortar and grout)
System 2+
EN 12878:2005
EN 12878:2005/AC:2006
FPC Certification Body
Inspection Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Fibres (for other uses in concrete, mortar and grout)
System 3
EN 14889-1:2006
EN 14889-2:2006
Testing Laboratory
Calculation body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Additions (Type II) (for concrete, mortar and grout)
System 1+
EN 13263-1:2005+A1:2009
EN 15167-1:2006
Inspection Body
Testing Laboratory
Product Certification Body
99/469/EC Products related to concrete, mortar and grout (2/2) :
• Concrete protection and repair products (for uses subject to reaction to fire regulations)
System 1
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
EN 1504-6:2006
Inspection Body
Testing Laboratory
Product Certification Body
99/469/EC Products related to concrete, mortar and grout (2/2) :
• Concrete protection and repair products (for uses subject to reaction to fire regulations)
System 3
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
EN 1504-6:2006
Testing Laboratory
99/470/EC Construction adhesives (1/2) :
• Adhesives for tiles (for internal and external uses in buildings and other civil engineering works)
System 3
EN 12004:2007
Testing Laboratory
Set page to normal font size Increase font size by 200 percentprint this page