Navigation path


Notification

Found : 40
  Body (History):

ASSOCIAÇÃO PORTUGUESA DE CERTIFICAÇÃO
Edifício de Serviços da Exponor, 2º, Av. Dr. António Macedo
4450-617 Leça da Palmeira
Country : Portugal

Phone : +351 229 993 600
Fax : +351 229 993 601

Email : info@apcer.pt
Website : www.apcer.pt

Notified Body number : 0866

Version(s): 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Last update : 26/11/2008
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
2004/22/EC Measuring Instruments Directive    
Last update : 15/10/2007
Products Procedures Articles/Annexes
Water Meters (Annex MI-001)
Gas Meters and Volume Conversion Devices (Annex MI-002)
   - except diaphragm gas meters
   - Volume Conversion Devices (subassembly)
Active Electrical Energy Meters (Annex MI-003)
Measuring Instruments for Liquids Other than Water (Annex MI-005)
   - Fuel dispensers
      - not liquefied gases
      - liquefied gases
   - Measuring systems on pipeline and systems for loading ships - all liquids
   - All other measuring systems [not stated elsewhere] – all liquids
   - Measuring systems on pipeline (accuracy class 0,3)
   - All measuring systems (accuracy class 0,5), in particular:
      - fuel dispensers (not for liquefied gases)
      - measuring systems on road tankers for liquids of low viscosity (<20 mPa.s)
      - measuring systems for (un)loading ships and rail and road tankers
      - measuring systems for milk
      - measuring systems for refuelling aircraft
   - Measuring systems for liquefied gases under pressure measured at a temperature equal to or above -10* (accuracy class 1,0):
      - measuring systems normally in class 0,3 or 0,5 but used for liquids whose temperature is less than -10*C or greater than 50*C
      - measuring systems normally in class 0,3 or 0,5 but used for liquids whose dynamic viscosity is higher than 1 000 mPa.s
      - measuring systems normally in class 0,3 or 0,5 but used for liquids whose maximum volumetric flowrate is not higher than 20 L/h
   - Measuring systems for liquefied carbon dioxide (accuracy class 1,5):
      - measuring systems for liquefied gases under pressure measured at a temperature below -10*C (other than cryogenic liquids)
   - Measuring systems for cryogenic liquids (temperature below -153*C) – accuracy class 2,5
Taximeters (Annex MI-007)
Declaration of conformity to type based on quality assurance of the production process Annex D
Material Measures (Annex MI-008)
   - Material measure of length
Declaration of conformity to type based on quality assurance of the production process
Declaration of conformity based on quality assurance of the production process
Declaration of conformity based on full quality assurance
Annex D
Annex D1
Annex H
Material Measures (Annex MI-008)
   - Capacity serving measures
Dimensional Measuring Instruments (Annex MI-009)
   - Length measuring instruments
      - for mechanical or electromechanical instruments
Declaration of conformity to type based on quality assurance of the production process
Declaration of conformity based on quality assurance of the production process
Declaration of conformity to type based on quality assurance of final product inspection and testing
Declaration of conformity based on quality assurance of final product inspection and testing
Declaration of conformity based on full quality assurance
Annex D
Annex D1
Annex E
Annex E1
Annex H
Dimensional Measuring Instruments (Annex MI-009)
   - Length measuring instruments
      - for electronic instruments or instruments containing software
Declaration of conformity to type based on quality assurance of the production process Annex D
Dimensional Measuring Instruments (Annex MI-009)
   - Area measuring instruments
      - for mechanical or electromechanical instruments
Declaration of conformity to type based on quality assurance of the production process
Declaration of conformity based on quality assurance of the production process
Declaration of conformity to type based on quality assurance of final product inspection and testing
Declaration of conformity based on quality assurance of final product inspection and testing
Declaration of conformity based on full quality assurance
Annex D
Annex D1
Annex E
Annex E1
Annex H
Dimensional Measuring Instruments (Annex MI-009)
   - Area measuring instruments
      - for electronic instruments or instruments containing software
Declaration of conformity to type based on quality assurance of the production process Annex D
Dimensional Measuring Instruments (Annex MI-009)
   - Multi-dimensional measuring instruments
      - for mechanical or electromechanical instruments
Declaration of conformity to type based on quality assurance of the production process
Declaration of conformity based on quality assurance of the production process
Declaration of conformity to type based on quality assurance of final product inspection and testing
Declaration of conformity based on quality assurance of final product inspection and testing
Declaration of conformity based on full quality assurance
Annex D
Annex D1
Annex E
Annex E1
Annex H
Dimensional Measuring Instruments (Annex MI-009)
   - Multi-dimensional measuring instruments
      - for electronic instruments or instruments containing software
Exhaust Gas Analysers (Annex MI-010)
Declaration of conformity to type based on quality assurance of the production process Annex D
Set page to normal font size Increase font size by 200 percentprint this page