Navigation path


Notification

Found : 39
  Body (History):

MATERIALPRÜFUNGSAMT FÜR DAS BAUWESEN DER TECHNISCHEN UNIVERSITÄT MÜNCHEN
Arcisstrasse, 21
80333 MÜNCHEN
Country : Germany

Phone : +49:89:28923022
Fax : +49:89:28923057

Email : ebert@mb.bv.tum.de
Website : -

Notified Body number : 1211

Version(s): 1 2 3 4 5 6 7 8 9

Last update : 14/09/2006
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products (History)
Last update : 14/09/2006                 Version(s): 1 2

Decision Product family, product /Intended use AoC system Technical specification Body function
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external application)
System 1
EN 13986:2002
Product Certification Body
Inspection Body
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external applications)
System 2+
EN 13986:2002
Inspection Body
97/555/EC Cements, building limes and other hydraulic binders :
• Common cements, including:<BR>-Portland cement,<BR>-Portland composite cements: Portland-slag cement, Portland-silica fume cement, Portland-pozzolana cement, Portland-fly ash cement, Portland-burnt shale cement, Portland-limestone cement, Portland composite cement,<BR>-Blastfurnace cements,<BR>-Pozzolanic cements,<BR>-Composite cements (preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products)
System 1+
EN 197-1:2000
EN 197-1:2000/ A1:2004
Inspection Body
Testing Laboratory
Product Certification Body
97/555/EC Cements, building limes and other hydraulic binders :
• Building limes, including:<BR>-Calcium limes,<BR>-Dolomitic limes,<BR>-Hydraulic limes (preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products)
System 2
EN 459-1:2001
FPC Certification Body
Inspection Body
97/740/EC Masonry and related products (1/3) :
• Masonry units category I (in walls, columns and partitions)
System 2+
EN 771-1:2003
EN 771-1:2003/A1:2005
EN 771-2:2003
EN 771-2:2003/A1:2005
EN 771-3:2003
EN 771-3:2003/A1:2005
EN 771-4:2003
EN 771-4:2003/A1:2005
EN 771-5:2003
EN 771-5:2003/A1:2005
FPC Certification Body
Inspection Body
97/740/EC Masonry and related products (1/3) :
• Factory-made, designed masonry mortars (in walls, columns and partitions)
System 2+
EN 998-2:2003
FPC Certification Body
Inspection Body
97/740/EC Masonry and related products (2/3) :
• Lintels (in walls and partitions)
System 3
EN 845-2:2003
Testing Laboratory
98/214/EC Structural metallic products and ancillaries (1/4) :
• Structural metallic sections/profiles: hot rolled, cold formed or otherwise produced sections/profiles with various shapes (T, L, H, U, Z, I, channels, angle, hollow, tubes), flat products (plate, sheet, strip), bars, castings, forgings made of various metallic materials, unprotected or protected against corrosion by coating (to be used in metal structures or in composite metal and concrete structures)
System 2+
EN 10025-1:2004
FPC Certification Body
Inspection Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Fascias and soffit boards (for uses subject to reaction to fire regulations)
• Roof windows (for uses subject to reaction to fire regulations)
• Rooflights (for uses subject to reaction to fire regulations)
• Factory-bonded composite or sandwich panels (for uses subject to reaction to fire regulations)
• Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations)
• Flat and profiled sheets (for uses subject to reaction to fire regulations)
System 1
ETA-04/0041
Product Certification Body
FPC Certification Body
98/436/EC Roof coverings, rooflights, roof windows and ancillary products (2/6) :
• Fascias and soffit boards (for uses subject to reaction to fire regulations)
• Roof windows (for uses subject to reaction to fire regulations)
• Rooflights (for uses subject to reaction to fire regulations)
• Factory-bonded composite or sandwich panels (for uses subject to reaction to fire regulations)
• Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations)
• Flat and profiled sheets (for uses subject to reaction to fire regulations)
System 3
ETA-04/0041
Testing Laboratory
98/456/EC Post-tensioning kits for the prestressing of structures (1/1) :
• Post-tensioning kits (for the prestressing of structures)
System 1+
ETAG 013
Product Certification Body
Inspection Body
Testing Laboratory
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Aggregates and fillers for concrete, mortar and grout (in buildings, roads and other civil engineering work)
System 2+
EN 12620:2002
EN 13043:2002
EN 13055-1:2002
EN 13139:2002
FPC Certification Body
Inspection Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Aggregates for unbound and hydraulically bound mixtures (for roads and other civil engineering works)
System 2+
EN 13242:2002
FPC Certification Body
Inspection Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Armourstones (for hydraulic structures and other civil engineering works)
System 2+
EN 13383-1:2002
FPC Certification Body
Inspection Body
98/598/EC Aggregates for uses with high safety requirements (2/2) :
• Railway ballast (for railway works)
System 2+
EN 13450:2002
FPC Certification Body
Inspection Body
98/599/EC Liquid applied roof waterproofing kits (3/3) :
• Liquid applied roof waterproofing kits (for uses subject to reaction to fire regulations)
System 1
ETAG 005
Product Certification Body
FPC Certification Body
98/599/EC Liquid applied roof waterproofing kits (3/3) :
• Liquid applied roof waterproofing kits (for uses subject to reaction to fire regulations)
System 3
ETAG 005
Testing Laboratory
99/90/EC Membranes (1/3) :
• Roof underlays (in buildings)
System 3
EN 13859-1:2005
Testing Laboratory
99/90/EC Membranes (1/3) :
• Water vapour control layers (in buildings)
System 3
EN 13859-1:2005
EN 13970:2004
EN 13984:2004
Testing Laboratory
99/90/EC Membranes (1/3) :
• Damp proofing sheets (in buildings)
System 2+
EN 13969:2004
FPC Certification Body
Inspection Body
99/90/EC Membranes (1/3) :
• Roof sheets (in buildings)
System 2+
EN 13707:2004
FPC Certification Body
Inspection Body
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 3
EN 13707:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 1
EN 13859-1:2005
EN 13970:2004
EN 13984:2004
Product Certification Body
Inspection Body
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 3
EN 13859-1:2005
EN 13970:2004
EN 13984:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 1
EN 13969:2004
Product Certification Body
FPC Certification Body
Inspection Body
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 3
EN 13969:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 1
EN 13859-1:2005
Product Certification Body
Inspection Body
99/90/EC Membranes (2/3) :
• Roof underlays (for uses subject to reaction to fire regulations)
System 3
EN 13859-1:2005
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 1
EN 13707:2004
Product Certification Body
FPC Certification Body
Inspection Body
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13162:2001
EN 13163:2001
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13170:2001
EN 13171:2001
EN 13171:2001/ A1:2004
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 1
EN 13162:2001
EN 13163:2001
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13170:2001
EN 13171:2001
EN 13171:2001/ A1:2004
Product Certification Body
Inspection Body
99/455/EC Timber frame and log prefabricated building kits (1/1) :
• Timber frame and log prefabricated building kits (as defined in Annex I) (in building works)
System 1
ETAG 007
ETAG 012
Product Certification Body
Inspection Body
Testing Laboratory
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Concrete protection and repair products (for other uses in buildings and civil engineering works)
System 2+
EN 1504-2:2004
EN 1504-4:2004
EN 1504-5:2004
FPC Certification Body
Inspection Body
99/469/EC Products related to concrete, mortar and grout (1/2) :
• Admixtures (for concrete, mortar and grout)
System 2+
EN 934-2:2001
EN 934-4:2001
FPC Certification Body
Inspection Body
99/469/EC Products related to concrete, mortar and grout (2/2) :
• Concrete protection and repair products (for uses subject to reaction to fire regulations)
System 1
EN 1504-2:2004
EN 1504-4:2004
Product Certification Body
FPC Certification Body
Inspection Body
99/469/EC Products related to concrete, mortar and grout (2/2) :
• Concrete protection and repair products (for uses subject to reaction to fire regulations)
System 3
EN 1504-2:2004
EN 1504-4:2004
Testing Laboratory
99/470/EC Construction adhesives (1/2) :
• Adhesives for tiles (for internal and external uses in buildings and other civil engineering works)
System 3
EN 12004:2001/A1:2002
Testing Laboratory
Set page to normal font size Increase font size by 200 percentprint this page