Navigation path


Notification

Found : 52
  Body (History):

FIRES, S.R.O.
Osloboditel'ov 282
059 35 BATIZOVCE
Country : Slovakia

Phone : +421:52:7129937
Fax : +421:52:7881412

Email : info@fires.sk
Website : -

Notified Body number : 1396

Version(s): 1 2 3 4 5 6 7 8 9 10 11 12 13

Last update : 12/09/2006
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products (History)
Last update : 12/09/2006                 Version(s): 1 2

Decision Product family, product /Intended use AoC system Technical specification Body function
95/467/EC Gypsum products (1/4) :
• Plasterboards and ceiling elements with thin laminations, fibrous gypsum boards, fibrous gypsum plaster casts, and composite panels (laminates), in which the incorporated material is placed on a face susceptible to be explosed to fire, including relevant ancillary products (in walls, partitions or ceilings (or lining thereof) subject to reaction to fire requirements)
System 3
EN 12859:2001
EN 12860:2001
Testing Laboratory
95/467/EC Gypsum products (2/4) :
• Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings)
System 3
EN 12859:2001
EN 12860:2001
Testing Laboratory
96/577/EC Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) :
• Smoke and heat exhaust ventilation systems-kits (fire safety)
System 1
EN 12101-2:2003
EN 12101-3:2002
Product Certification Body
Inspection Body
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 1
EN 13830:2003
Product Certification Body
Inspection Body
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
• Curtain wall kits (as external walls not subject to reaction to fire requirements)
System 3
EN 13830:2003
Testing Laboratory
96/582/EC Structural sealant glazing kits of types (curtain walling) :
• Structural sealant glazing kits, Types II and IV (for external walls and roofs)
System 1
ETAG 002 - 1
ETAG 002 - 2
ETAG 002 - 3
Product Certification Body
Inspection Body
Testing Laboratory
97/462/EC Wood-based panels (1/2) :
• Unfaced overlaid and veneered or coated wood-based panels (for structural elements in internal or external application)
System 1
EN 13986:2002
Testing Laboratory
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 1
EN 13986:2002
Testing Laboratory
97/462/EC Wood-based panels (2/2) :
• Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications)
System 3
EN 13986:2002
Testing Laboratory
97/556/EC External thermal insulation composite systems/kits with rendering (ETICS)(1/1) :
• External thermal insulation composite systems/kits with rendering (ETICS) (in external wall subject to fire regulations)
System 1
ETAG 004
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 3
EN 14041:2004
Testing Laboratory
97/808/EC Floorings (2/2) :
• Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses)
System 1
EN 14041:2004
Testing Laboratory
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 3
EN 13813:2002
Testing Laboratory
97/808/EC Floorings (2/2) :
• Floor screed materials (for internal uses)
System 1
EN 13813:2002
Testing Laboratory
98/213/EC Internal partition kits (1/5) :
• Internal partition kits (for uses subject to reaction to fire requirements)
System 1
ETAG 003
Inspection Body
Testing Laboratory
Product Certification Body
98/213/EC Internal partition kits (1/5) :
• Internal partition kits (for uses subject to reaction to fire requirements)
System 3
ETAG 003
Testing Laboratory
98/213/EC Internal partition kits (2/5) :
• Internal partition kits (for fire compartmentation)
System 3
ETAG 003
Testing Laboratory
98/213/EC Internal partition kits (4/5) :
• Internal partition kits (for uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
ETAG 003
Testing Laboratory
98/279/EC Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1) :
• Non load-bearing permanent shuttering kits/systems, to be filled with normal concrete and, where relevant, with reinforcement, based on either: hollow blocks made of an insulating material (or a combination of an insulating material and other materials) (for the construction of external and internal walls subject to fire regulations, in buildings)
System 1
ETAG 009
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (1/5) :
• Suspended ceilings (kits) (as internal or external finishes used for fire protection of ceilings)
System 3
EN 13964:2004
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (2/5) :
• Suspended ceilings (kits) (as internal or external finish in ceilings subject to safety in use requirements)
System 3
EN 13964:2004
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Coverings in roll form (as internal finishes in walls or ceilings subject to reaction to fire regulations)
System 1
EN 14716:2004
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Coverings in roll form (as internal finishes in walls or ceilings subject to reaction to fire regulations)
System 3
EN 14716:2004
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations)
System 1
EN 13964:2004
Product Certification Body
Inspection Body
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (3/5) :
• Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations)
System 3
EN 13964:2004
Testing Laboratory
98/437/EC Internal and external wall and ceiling finishes (4/5) :
• Suspended ceilings (kits) (as internal or external finishes in walls or ceilings subject to regulations on dangerous substances)
System 3
EN 13964:2004
Testing Laboratory
98/599/EC Liquid applied roof waterproofing kits (1/3) :
• Liquid applied roof waterproofing kits (for all roof waterproofing uses)
System 3
ETAG 005
Testing Laboratory
98/599/EC Liquid applied roof waterproofing kits (2/3) :
• Liquid applied roof waterproofing kits (for uses subject to external fire performance regulations)
System 3
ETAG 005
Testing Laboratory
98/599/EC Liquid applied roof waterproofing kits (3/3) :
• Liquid applied roof waterproofing kits (for uses subject to reaction to fire regulations)
System 1
ETAG 005
Testing Laboratory
98/599/EC Liquid applied roof waterproofing kits (3/3) :
• Liquid applied roof waterproofing kits (for uses subject to reaction to fire regulations)
System 3
ETAG 005
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (1/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for use in roofs and roof finishes)
System 3
ETAG 010
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (2/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to external fire performance regulations)
System 3
ETAG 010
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (3/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
System 1
ETAG 010
Testing Laboratory
98/600/EC Self-supporting translucent roof kits (except glass-based kits) (3/3) :
• Self-supporting translucent roof kits (except glass-based kits) (for uses subject to reaction to fire regulations)
System 3
ETAG 010
Testing Laboratory
99/89/EC Prefabricated stair kits (2/2) :
• Prefabricated stair kits (for uses subject to reaction to fire regulations)
System 1
ETAG 008
Testing Laboratory
99/89/EC Prefabricated stair kits (2/2) :
• Prefabricated stair kits (for uses subject to reaction to fire regulations)
System 3
ETAG 008
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 1
EN 13967:2004
EN 13969:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Damp proofing sheets (for uses subject to reaction to fire regulations)
System 3
EN 13967:2004
EN 13969:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 1
EN 13707:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Roof sheets (for uses subject to reaction to fire regulations)
System 3
EN 13707:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 1
EN 13859-2:2004
EN 13970:2004
EN 13984:2004
Testing Laboratory
99/90/EC Membranes (2/3) :
• Water vapour control layers (for uses subject to reaction to fire regulations)
System 3
EN 13859-2:2004
EN 13970:2004
EN 13984:2004
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 3
EN 13162:2001
EN 13163:2001
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13170:2001
EN 13171:2001
EN 13171:2001/ A1:2004
Testing Laboratory
99/91/EC Thermal insulating products (2/2) :
• Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire)
System 1
EN 13162:2001
EN 13163:2001
EN 13164:2001
EN 13164:2001/ A1:2004
EN 13165:2001
EN 13165:2001/ A1:2004
EN 13166:2001
EN 13166:2001/ A1:2004
EN 13167:2001
EN 13167:2001/ A1:2004
EN 13168:2001
EN 13168:2001/ A1:2004
EN 13169:2001
EN 13169:2001/ A1:2004
EN 13170:2001
EN 13171:2001
EN 13171:2001/ A1:2004
Testing Laboratory
99/92/EC Light composite wood-based beams and columns (1/1) :
• Light composite wood-based beams and columns (including T-beams, i.e. beam/slab combinations) (in buildings)
System 1
ETAG 011
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
System 3
EN 13241-1:2003
Testing Laboratory
99/454/EC Fire stopping, fire sealing and fire protective products (2/2) :
• Fire stopping and fire sealing products (for uses subject to reaction to fire regulations)
• Fire protective products (including coatings) (for uses subject to reaction to fire regulations)
System 1
ETAG 018 - 1
ETAG 018 - 4
Product Certification Body
Inspection Body
Testing Laboratory
99/454/EC Fire stopping, fire sealing and fire protective products (2/2) :
• Fire stopping and fire sealing products (for uses subject to reaction to fire regulations)
• Fire protective products (including coatings) (for uses subject to reaction to fire regulations)
System 3
ETAG 018 - 1
ETAG 018 - 4
Testing Laboratory
99/455/EC Timber frame and log prefabricated building kits (1/1) :
• Timber frame and log prefabricated building kits (as defined in Annex I) (in building works)
System 1
ETAG 007
ETAG 012
Testing Laboratory
99/470/EC Construction adhesives (1/2) :
• Adhesives for tiles (for internal and external uses in buildings and other civil engineering works)
System 3
EN 12004:2001/A1:2002
Testing Laboratory
99/472/EC Pipes, tanks and ancillaries not in contact with water intended for human consumption (1/5) :
• Fittings, adhesives, joints, joint sealings and gaskets (in installations for the transport/distribution/ storage of gas/fuel intended for the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building)
System 3
EN 682:2002
Testing Laboratory