Navigation path


Notification

Found : 20
  Body (History):

IFT ROSENHEIM GMBH
Theodor-Gietl-Strasse 7-9
83026 ROSENHEIM
Country : Germany

Phone : +49:80:31-2610
Fax : +49:80:31-261290

Email : sieberath@ift-rosenheim.de
Website : -

Notified Body number : 0757

Version(s): 1 2 3 4 5 6 7

Last update : 17/08/2006
 

Return to legislation list

Some information about the accreditation details are available in the PDF
Legislation
89/106/EEC Construction products (History)
Last update : 17/08/2006                 Version(s): 1 2

Decision Product family, product /Intended use AoC system Technical specification Body function
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
System 1
EN 13830:2003
Testing Laboratory
96/580/EC Curtain wallings (1/1) :
• Curtain wall kits (as external walls subject to reaction to fire requirements)
• Curtain wall kits (as external walls not subject to reaction to fire requirements)
System 3
EN 13830:2003
Testing Laboratory
96/582/EC Structural sealant glazing kits of types (curtain walling) :
• Structural sealant glazing kits, Types II and IV (for external walls and roofs)
System 1
ETAG 002 - 1
ETAG 002 - 2
ETAG 002 - 3
Product Certification Body
Inspection Body
Testing Laboratory
96/582/EC Structural sealant glazing kits of types (curtain walling) :
• Structural sealant glazing kits, Types I and III (for external walls and roofs)
System 2+
ETAG 002 - 1
ETAG 002 - 2
ETAG 002 - 3
FPC Certification Body
Inspection Body
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes)
System 1
EN 1125:1997/A1:2001
EN 179:1997/A1:2001
EN 1935:2002
Product Certification Body
Inspection Body
Testing Laboratory
99/93/EC Doors, windows, shutters, blinds, gates and related building hardware (1/1) :
• Doors and gates (with or without related hardware) (other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes))
System 3
EN 13241-1:2003
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Flat or curved glass panels (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
Product Certification Body
Inspection Body
2000/245/EC Flat glass, profiled glass and glass-block products (1/6) :
• Insulating glass units (for use in a glazed assembly intended specifically to provide fire resistance)
System 1
EN 1279-5:2005
Inspection Body
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Flat or curved glass panels (for uses subject to reaction to fire regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (2/6) :
• Insulating glass units (for uses subject to reaction to fire regulations)
System 3
EN 1279-5:2005
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Flat or curved glass panels (for uses subject to external fire performance regulations)
System 3
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (3/6) :
• Insulating glass units (for uses subject to external fire performance regulations)
System 3
EN 1279-5:2005
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Flat or curved glass panels (for other uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Flat or curved glass panels (for use as anti-bullet, or anti-explosion glazing)
System 1
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Product Certification Body
Inspection Body
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Insulating glass units (for use as anti-bullet, or anti-explosion glazing)
System 1
EN 1279-5:2005
Inspection Body
Product Certification Body
2000/245/EC Flat glass, profiled glass and glass-block products (4/6) :
• Insulating glass units (for other uses liable to present "safety-in-use" risks and subject to such regulations)
System 3
EN 1279-5:2005
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) :
• Flat or curved glass panels (specially treated) (for uses relating to energy conservation and/or noise reduction)
System 3
EN 1096-4:2004
EN 12150-2:2004
EN 12337-2:2004
EN 1279-5:2005
EN 13024-2:2004
EN 14178-2:2004
EN 14179-2:2005
EN 14321-2:2005
EN 14449:2005
EN 1748-1-2:2004
EN 1748-2-2:2004
EN 1863-2:2004
EN 572-9:2004
Testing Laboratory
2000/245/EC Flat glass, profiled glass and glass-block products (5/6) :
• Insulating glass units (for uses relating to energy conservation and/or noise reduction)
System 3
EN 1279-5:2005
Testing Laboratory
Set page to normal font size Increase font size by 200 percentprint this page